CHECKING GAS

CONNECTIONS

WARNING: Test all gas pip- ing and connections for leaks after installing or servicing. Cor- rect all leaks at once.

WARNING: Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once.

CAUTION: Make sure exter- nal regulator has been installed between propane/LP supply and heater. See guidelines under Con- necting to Gas Supply, page 12.

Test Pressures Equal To or Less Than 1/2 PSIG

1.Close manual shutoff valve (see Fig- ure 15).

2.Pressurize supply piping system by ei- ther using compressed air or opening propane/LP supply tank valve.

3.Check all joints from propane/LP sup- ply tank to manual shutoff valve (see Figure 16). Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak.

4.Correct all leaks at once.

Manual

Shutoff Open

Valve

Closed

Figure 15 - Manual Shutoff Valve

Pressure Testing Heater Gas Connections

1.Open manual shutoff valve (see Fig- ure 15).

2.Open propane/LP supply tank valve.

3.Make sure control knob of heater is in the OFF position.

4.Check all joints from manual shutoff valve to control valve (see Figure 16). Apply mixture of liquid soap and wa- ter to gas joints. Bubbles forming show a leak.

5.Correct all leaks at once.

6.Light heater (see Operating Heater, pages 15 and 16). Check all other in- ternal joints for leaks.

7.Turn off heater (see To Turn Off Gas to Appliance, page 16).

Pressure Testing Gas Supply Piping System

Test Pressures In Excess Of 1/2 PSIG

1.

Disconnect heater and its individual

 

manual shutoff valve from gas supply

 

piping system. Pressures in excess of

 

1/2 psig will damage heater regulator.

2.

Cap off open end of gas pipe where

 

manual shutoff valve was connected.

3.

Pressurize supply piping system by ei-

 

ther using compressed air or

 

opening propane/LP supply tank valve.

4.

Check all joints of gas supply piping

 

system. Apply mixture of liquid soap

 

and water to gas joints. Bubbles form-

 

ing show a leak.

Propane/LP Supply Tank

Manual

Control Valve

Shutoff

Location

Valve

 

5.

Correct all leaks at once.

6.

Reconnect heater and manual shutoff

 

valve to gas supply. Check reconnected

 

fittings for leaks.

Figure 16 - Checking Gas Joints

Continued

105192

13

Page 13
Image 13
Desa FVF24P Checking GAS Connections, Pressure Testing Heater Gas Connections, Pressure Testing Gas Supply Piping System

FVF30P, FVF18P, FVF24P specifications

Desa FVF24P, FVF18P, and FVF30P are innovative products in the heating and ventilation sector, designed to meet diverse customer needs while optimizing performance. Each model has unique features and technologies that cater to various applications whether residential, commercial, or industrial.

Starting with the FVF24P, this model is renowned for its high efficiency and compact design. It is equipped with advanced modulation technology which allows the unit to adjust its output based on real-time demand. This results in reduced energy consumption and lower operating costs. The FVF24P also boasts an integrated smart control system that enables users to monitor and manage settings remotely via smartphone applications. This feature not only enhances convenience but also maximizes comfort by ensuring optimal temperature levels at all times.

Moving on to the FVF18P, this model is specifically engineered for smaller spaces or apartments where heating efficiency is paramount without compromising on space. It incorporates a unique heat exchanger that significantly increases heat transfer efficiency. Additionally, the FVF18P features a quiet operation mode, making it suitable for bedrooms or any noise-sensitive environments. Its compact size does not detract from its performance, as it offers a balanced air distribution system ensuring every corner receives adequate warmth.

The FVF30P, on the other hand, is a powerhouse designed for larger areas requiring robust heating capabilities. It supports a wider range of airflow settings and has an impressive BTU rating, making it ideal for vast commercial spaces or industrial applications. The inclusion of multiple safety features, such as overheat protection and automatic shut-off, underscores its design philosophy focused on user safety and reliability. Furthermore, the FVF30P is built to work with renewable energy sources, aligning with modern sustainability goals and reducing the environmental impact associated with traditional heating solutions.

In summary, the Desa FVF series presents a range of efficient heating solutions with the FVF24P, FVF18P, and FVF30P models catering to different power requirements and space constraints. With advanced technologies such as smart controls, enhanced heat exchangers, and safety features, these models are a testament to Desa’s commitment to quality, efficiency, and customer satisfaction in the heating market.