OWNER’S MANUAL

CLEANING AND MAINTENANCE

WARNING: Turn off heater and let cool before cleaning.

CAUTION: You must keep control areas, burner, and circu- lating air passageways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a quali- fied service person. Heater may need more frequent cleaning due to excessive lint from carpeting, pet hair, bedding materials, etc.

CLEANING BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLE

The primary air inlet holes allow the proper amount of air to mix with the gas. This provides a clean burning flame. Keep these holes clear of dust, dirt, and lint. Clean these air inlet holes prior to each heating season. Blocked air holes will create soot. We rec- ommend that you clean the unit every 2,500 hours of operation or every three months.

We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt. To clean these parts we recom- mend using compressed air no greater than 30 PSI. Your local computer store, hard- ware store, or home center may carry com- pressed air in a can. You can use a vacuum cleaner in the blow position. If using com- pressed air in a can, please follow the direc- tions on the can. If you don't follow direc- tions on the can, you could damage the pilot assembly.

1.Shut off the unit, including the pilot. Allow the unit to cool for at least thirty minutes.

2.Inspect burner, pilot, and primary air inlet holes on injector holder for dust and dirt (see Figure 34).

3.Blow air through the ports/slots and holes in the burner.

4.Check the injector holder located at the end of the burner tube again. Remove any large particles of dust, dirt, lint, or pet hairs with a soft cloth or vacuum cleaner nozzle.

5.Blow air into the primary air holes on the injector holder.

6.In case any large clumps of dust have now been pushed into the burner repeat steps 3 and 4.

Clean the pilot assembly also. A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly. There is a small pilot air inlet hole about two inches from where the pilot flame comes out of the pilot assembly (see Figure 35). With the unit off, lightly blow air through the air inlet hole. You may blow through a drinking straw if compressed air is not available.

 

Injector Holder

Burner

(May Be Brass

or Aluminum

Tube

Depending on

 

 

Model)

Primary Air Inlet Holes (Shape of Holes May Vary by Model)

Figure 34 - Injector Holder On Outlet Burner Tube

Ports/Slots

Burner

Tube

Pilot

Assembly

Pilot Air

Inlet

Hole

Figure 35 - Pilot Inlet Air Hole

LOGS

If you remove logs for cleaning, refer to Installing Logs, page 14 to properly re- place logs.

Replace log(s) if broken or chipped (dime-sized or larger).

MAIN BURNER

Periodically inspect all burner flame holes with the heater running. All slotted burner flame holes should be open with yellow flame present. All round burner flame holes should be open with a small blue flame present. Some burner flame holes may be- come blocked by debris or rust, with no flame present. If so, turn off heater and let cool. Either remove blockage or replace burner. Blocked burner flame holes will create soot.

REPLACEMENT PARTS

Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized dealers of this product. If they can’t supply original replacement part(s), call DESA International’s Technical Service Department at 1-800-323-5190. When call- ing DESA International, have ready

your name and address

model and serial numbers of your heater

how heater was malfunctioning

type of gas used (propane/LP or natural gas)

purchase date

Usually, we will ask you to return the defec- tive part to the factory.

PARTS NOT UNDER

WARRANTY

Contact authorized dealers of this product. If they can’t supply original replacement part(s), call DESA International’s Parts Department at 1-800-972-7879 for referral information. When calling DESA Interna- tional, have ready

model number of your heater

the replacement part number

104342

23

Page 23
Image 23
Desa GAS LOG HEATER installation manual Cleaning and Maintenance, Replacement Parts

GAS LOG HEATER specifications

Desa GAS LOG HEATER is a popular heating solution that brings the warmth and ambiance of a traditional fireplace to modern living spaces. Renowned for its efficiency and aesthetic appeal, this gas log heater is designed to replicate the flickering flames and the cozy feel of a wood-burning fire without the associated hassles.

One of the primary features of the Desa GAS LOG HEATER is its realistic flame effect, which is created using advanced gas log technology. The heater utilizes artificial logs that are crafted to resemble real wood, enhancing the visual appeal and creating a nostalgic atmosphere. The flames are adjustable, allowing users to customize the intensity based on their preferences and heating needs.

Efficiency is a hallmark of the Desa GAS LOG HEATER. Equipped with a high-efficiency heating system, it effectively converts gas to heat, ensuring that energy consumption is kept to a minimum. This results in lower utility bills and a reduced carbon footprint, making it an environmentally friendly option for homeowners. The heater's BTU output can vary, allowing it to accommodate different room sizes and layouts.

The Desa GAS LOG HEATER also features easy ignition systems, which simplify the startup process. Many models come with an automatic ignition option or a push-button start, eliminating the need for matches or lighter. Furthermore, they often include adjustable heat settings, enabling users to control the temperature easily.

Safety is a critical concern with gas heaters, and Desa addresses this with built-in safety features. These may include safety shut-off valves, thermocouple sensors, and automatic shut-off systems that activate in case of malfunction or if the heater tips over. This provides peace of mind for families with children or pets.

Installation of the Desa GAS LOG HEATER is generally straightforward, especially compared to traditional wood-burning fireplaces. Many units can be vented directly through an exterior wall, reducing the need for extensive chimney systems. This versatility allows homeowners to place the heater in various locations, enhancing the overall design of their spaces.

In summary, the Desa GAS LOG HEATER combines style, efficiency, and safety to deliver a reliable heating solution. Its realistic flames and efficient operation make it an attractive choice for anyone seeking to enjoy the charm of a fireplace without the complexities of wood burning. As energy efficiency and environmental consciousness continue to rise, the Desa GAS LOG HEATER stands out as a smart option for modern homes.