Pump Rotor

(Procedure if rotor is binding)

1.Remove upper shell (see page 10).

2.Remove filter end cover screws using 5/16" nut- driver.

3.Remove filter end cover and air filters.

4.Remove pump plate screws using 5/16" nut- driver.

5.Remove pump plate.

6.Remove rotor, insert, and blades.

7.Check for debris in pump. If debris is found, blow out with compressed air.

8.Install insert and rotor.

9.Check gap on rotor. Adjust to .003"/.004" (.076/.101 mm) if needed (see Figure 33).

Note: Rotate rotor one

full turn to insure the gap is

.003"/.004" (.076/.101 mm) at tightest position. Adjust if needed.

10.Install blades, pump plate, air filters, and filter end cover.

11.Replace fan guard and upper shell.

12.Adjust pump pressure (see page 14).

Note: If rotor is still binding, proceed as follows.

13.Perform steps 1 thru 6 above.

14.Place fine grade sandpaper (600 grit) on flat surface. Sand rotor lightly in “figure 8” motion four times (see Figure 34).

15.Reinstall insert and rotor.

16.Perform steps 10 thru 12 above.

18

Blade

Air

Pump

Intake

 

Plate

 

Filter

 

 

 

 

 

 

Filter End

 

 

 

Cover

 

 

 

 

Fan Guard

 

 

 

(90,000 BTU/Hr

Insert

 

 

Model Shown)

 

 

 

Rotor

 

 

 

Air Output

 

 

 

Filter

 

 

 

Figure 31 - Rotor Location, 30/70,000 BTU/Hr Models

Blade

Pump

 

 

Plate

 

 

 

 

 

 

 

Air

 

 

 

Intake

 

 

 

Filter

 

 

 

Filter End

 

 

Cover

Fan Guard

 

 

 

(90,000 BTU/Hr

Insert

 

 

Model Shown)

 

 

 

Rotor

 

 

 

Air

 

 

 

Output

 

 

 

Filter

 

 

 

Figure 32 - Rotor Location, 90/150,000 BTU/Hr Models

Gap Adjusting

 

Screw

 

 

.003"/.004" (.076/.101 mm) Gap

 

Measured With Feeler Gauge

 

Sandpaper

Blade

Rotor

Gap

 

Adjusting

 

Screw

 

Figure 33 - Gap Adjusting

 

Screw Locations

Figure 34 - Sanding Rotor

099605

Page 18
Image 18
Desa H.S.I. Series owner manual Pump Rotor, Rotor Location, 30/70,000 BTU/Hr Models