Extension Cords

CAUTION: Use only extension cords marked for outdoor use.

Be sure to use the right size extension cord. If cord size is wrong, tool may be damaged. Tool performance may also be affected.

Extension Cord Size Requirement 1 to 25 feet, use 16 AWG rated cord 26 to 50 feet, use 14 AWG rated cord

Inspect extension cords often and replace if damaged.

Loading Tool

WARNING: Never load tool while it is plugged in. Accidental discharge may occur. Before loading, move trigger lock to the OFF position and unplug tool.

1.Move trigger lock to the OFF position (see Figure 1) and unplug tool.

2.Turn tool upside down.

3.Press in latch lock and slide staple chamber cover back until fully open (see Figures 2 and 3).

Latch

Lock

Trigger Lock In

Off Position

Figure 1

Staple

Chamber

Cover

Figure 2

Figure 3

Continued

112787

5

 

Page 5
Image 5
Desa HH34392 operating instructions Extension Cords, Loading Tool