Horizontal Termination Configurations

10

VENTING INSTALLATION INSTRUCTIONS

Installation Planning (Cont.)

VENTING INSTALLATION INSTRUCTIONS

Continued

10.Place fireplace into position and shim with noncombustible ma- terial if needed. Nail or screw side flanges to framing to secure unit in place. IMPORTANT: Make sure fireplace is level before securing. If fireplace is not level it will not work properly.

Minimum Pipe

Siding Standoff

Overlap 11/4"

 

 

Screws

Direct Vent

 

Pipe

 

Wall

 

Firestop

 

Maintain 1"

 

Minimum Air

 

Space Around

 

Outer Pipe When

 

Penetrating a Wall

High Wind

 

Termination

10 3/4" x 10 3/4"

Apply Mastic to

Framed

Opening

Outside Edge of

 

Standoff

 

Exterior Wall

 

with Vinyl Siding

Figure 13 - Typical Horizontal Termination Cap Mounting with Additional Siding Standoff Installed

Horizontal Termination Configurations

Figures 14 through 18 show different configurations and alternatives for venting with horizontal termination. Each figure includes a chart with critical minimum and maximum dimensions which MUST be met. IMPORTANT: Remember that a horizontal run of venting must have a 1/4" rise for every 12" of run toward the termination.

Manual background WARNING: Never run vent downward as this may cause excessive temperatures which could cause a fire. Operation of improperly installed and main- tained venting system could result in serious injury, property damage or loss of life.

GROUND FLOOR INSTALLATION

Recommended Applications:

Installation using cabinet surrounds

Through the wall using round or square termination (up to 12" horizontal pipe)

NOT FOR CORNER INSTALLATION

45° Elbow

Horizontal High

Wind Square

Termination

Adjustable

Pipe 12" Max.

Wall

Firestop

Square Termination

Vertical (V) Horizontal (H)

32 3/4"

17" max.

45° Elbow

Wall

 

Exterior Portion of Wall

Firestop

 

Firestop (Round

 

 

 

 

 

Termination Only)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Horizontal

Round

Termination

Figure 14 - Horizontal Termination Configuration for Square or Round Termination

Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundForManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background.Manual backgroundManual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual backgroundManual background

111924-01A

Page 10
Image 10
Desa K36EP, K36EN installation manual Venting Installation Instructions, Continued, Horizontal Termination Configurations