TROUBLESHOOTING

22

TROUBLESHOOTING

Note: For additional help, visit DESA Heating Products’ technical service web site at www.desatech.com.

Note: All troubleshooting items are listed in order of operation.

WARNING: Turn off and let cool before servicing. Only a qualified service person should service and repair heater.

CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/ pilot unit.

 

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

 

When ignitor button is pressed, there is no

1.

Ignitor electrode not connected to igni-

1.

Reconnect ignitor cable

 

spark at ODS/pilot

 

tor cable

 

 

 

 

2.

Ignitor cable pinched or wet

2.

Free ignitor cable if pinched by any

 

 

 

 

 

metal or tubing. Keep ignitor cable dry

 

 

3.

Piezo ignitor nut is loose

3.

Tighten nut holding piezo ignitor to base

 

 

 

 

 

panel of log set. Nut is located behind

 

 

 

 

 

base panel.

 

 

4.

Broken ignitor cable

4.

Replace ignitor cable

 

 

5.

Bad piezo ignitor

5.

Replace piezo ignitor

 

 

6.

Ignitor electrode positioned wrong

6.

Replace pilot assembly

 

 

7.

Ignitor electrode broken

7.

Replace pilot assembly

 

 

 

 

 

 

 

When ignitor button is pressed, there is

1.

Gas supply turned off or equipment

1.

Turn on gas supply or open equipment

 

spark at ODS/pilot but no ignition

 

shutoff valve closed

 

shutoff valve

 

 

2.

Control knob not in PILOT position

2.

Turn control knob to PILOT position

 

 

3.

Control knob not pressed in while in

3.

Press in control knob while in PILOT

 

 

 

PILOT position

 

position

 

 

4.

Air in gas lines when installed

4.

Continue holding down control knob.

 

 

 

 

 

Repeat igniting operation until air is

 

 

 

 

 

removed

 

 

5.

Depleted gas supply (propane/LP only)

5.

Contact local propane/LP gas company

 

 

6.

ODS/pilot is clogged

6.

Clean ODS/pilot (see Cleaning and

 

 

 

 

 

Maintenance, page 21) or replace ODS/

 

 

 

 

 

pilot assembly

 

 

7.

Gas regulator setting is not correct

7.

Replace gas regulator

 

 

 

 

 

 

 

ODS/pilot lights but flame goes out when

1.

Control knob not fully pressed in

1.

Press in control knob fully

 

control knob is released

2.

Control knob not pressed in long enough

2.

After ODS/pilot lights, keep control

 

 

 

 

 

knob pressed in 30 seconds

 

 

3.

Equipment shutoff valve not fully open

3.

Fully open equipment shutoff valve

 

 

4.

Pilot flame not touching thermocouple,

4.

A) Contact local natural or propane/LP

 

 

 

which allows thermocouple to cool,

 

gas company

 

 

 

causing pilot flame to go out. This prob-

 

 

 

 

 

lem could be caused by one or both of

 

B) Clean ODS/pilot (see Cleaning and

 

 

 

the following:

 

Maintenance, page 21) or replace ODS/

 

 

 

A) Low gas pressure

 

pilot assembly

 

 

 

B) Dirty or partially clogged ODS/pilot

 

 

 

 

5.

Thermocouple connection loose at con-

5.

Hand tighten until snug, then tighten

 

 

 

trol valve

 

1/4 turn more

 

 

6.

Thermocouple damaged

6.

Replace pilot assembly

 

 

7.

Control valve damaged

7.

Replace control valve

For..com

111604-01B

Page 22
Image 22
Desa LMFP33PR installation manual Troubleshooting, Observed Problem Possible Cause Remedy

LMFP33PR specifications

Desa LMFP33PR is an advanced multipurpose electronic system that has gained attention for its impressive range of features and robust performance. Designed to cater to both commercial and residential applications, this device brings a blend of efficiency, flexibility, and user-friendliness to various tasks.

One of the standout features of the Desa LMFP33PR is its high power output, making it suitable for demanding applications. With a maximum wattage capacity that outstrips many competitors in its category, this device can handle significant loads, making it an ideal choice for businesses that require reliable energy sources. Its ability to support multiple devices simultaneously ensures that users can optimize productivity without compromising on performance.

In terms of technology, the Desa LMFP33PR incorporates innovative energy management systems. The integrated smart technology allows users to monitor energy consumption in real-time, offering insights into usage patterns. This can lead to informed decisions regarding energy use, ultimately resulting in cost savings and operational efficiency. Furthermore, the device is equipped with advanced safety features, including overload protection and surge suppression, which safeguards both the unit and connected devices.

The build quality of the Desa LMFP33PR is another aspect worth highlighting. Constructed from durable materials, it is designed to withstand the rigors of frequent use, making it ideal for environments where reliability is paramount. The compact design ensures that it can fit into various spaces without occupying too much physical room, a feature especially appreciated in busy work settings.

User experience is enhanced by an intuitive interface that simplifies operation. The inclusion of programmable settings allows users to customize its functionality according to their specific needs, adding a layer of convenience. Additionally, the Desa LMFP33PR is designed to be energy-efficient, aligning with the growing demand for sustainable solutions. By minimizing energy waste, this device contributes to environmentally friendly operations.

Finally, with customer support and service options readily available, users can access assistance whenever needed, ensuring a seamless experience throughout the lifecycle of the product. In conclusion, the Desa LMFP33PR stands out as a versatile and efficient solution for anyone in need of reliable electric management systems, combining power, durability, and smart technology in one package.