Desa RCLP100V owner manual Operation, To Start Heater, To Stop Heater

Models: RCLP100V

1 28
Download 28 pages 61.77 Kb
Page 5
Image 5

INSTALLATION

Continued

5.Check all connections for leaks.

6.Close propane supply valve.

Regulator Hose

Supply Valve

 

Vent

Propane

(pointing

down)

Tank

Fuel Gas

 

 

Connector

Figure 3 - Regulator With Vent Pointing

 

Down

100,000 Btu/Hr

 

Model Shown

 

Inlet

Connector

Hose

Figure 4 - Hose and Inlet Connector

OPERATION

WARNING: Review and un- derstand the warnings in the Safety Information section, page

2.They are needed to safely op- erate this heater. Follow all local codes when using this heater.

TO START HEATER

1.Follow all installation, ventilation and safety information.

2.Locate heater on stable and level surface. Make sure strong drafts do not blow into front or rear of heater.

3.Make sure the control knob is in the OFF

position.

4.Plug power cord of heater into a three-prong, grounded extension cord. Extension cord must be at least 6 ft. (2 m) long, UL/CSA listed, and of a proper size.

Extension Cord Size Requirement

Up to 100 ft. (30 m) long, use 16 AWG rated cord.

101 to 200 ft. (31 to 60 m) long, use 14 AWG rated cord.

5.Plug extension cord into a 120 volt/60 hertz, 3-hole, grounded outlet. Motor will start. Fan will turn, forcing air out front of heater.

6.Open propane supply valve on propane tank(s) slowly. Note: If not opened slowly, excess- flow check valve on propane tank will stop gas flow. If this happens, close propane supply valve and open again slowly.

7.Press and hold in control knob. Turn counter- clockwise to the LOW position. Heater should ignite within a few seconds.

Note: If heater fails to ignite, hose may have air in it. If so, keep automatic control valve button pressed and wait 20 seconds. Release automatic control valve button and wait 20 seconds for unburned fuel to exit heater. Repeat step 7.

8.After heater ignites, wait 30 seconds then release the control knob. This activates the automatic control system.

9.When burner remains lit, set heater at the desired heat level by turning the control valve counterclockwise. If burner goes out, turn off gas. Turn control knob fully clockwise to the lowest position. Check fuel supply. If adequate fuel is available, restart heater beginning at step #1.

TO STOP HEATER

1.Tightly close propane supply valve on propane tank(s).

2.Wait a few seconds. Heater will burn gas left in supply hoses.

3.Turn control knob to the OFF position.

4.Unplug heater.

103908-01E

www.desatech.com

5

Page 5
Image 5
Desa RCLP100V Operation, To Start Heater, To Stop Heater, Check all connections for leaks Close propane supply valve