Desa RCLP50A owner manual Ventilation Operation, To Start Heater, Continued, Installation

Models: RCLP50A

1 36
Download 36 pages 42.12 Kb
Page 7
Image 7
VENTILATION

INSTALLATION

Continued

VENTILATION

OPERATION

4.Open propane supply valve on propane tank(s) slowly. Note: If not opened slowly, excess-flow check valve on propane tank will stop gas flow. If this happens, close propane supply valve and open again slowly.

5.Check all connections for leaks.

To Start HeaterWARNING

Never use an open flame to check for a leak. Apply a mix- ture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once.

6. Close propane supply valve.

ContinuedWARNING

Provide at least a 0.14 m2 (1.5-square-foot) opening of fresh, outside air while running heater. If proper fresh, outside air ventilation is not provided, carbon monoxide poisoning can occur. Provide proper fresh, outside air ventilation before running heater.

IMPORTANT: Provide extra fresh air if more heaters are being used.

Manual backgroundWARNING

Review and understand the warnings in the Safety Informa- tion section, pages 2 and 3. They are needed to safely operate this heater. Follow all local codes when using this heater.

To Start Heater

1.Follow all installation, ventilation, and safety information.

2.Locate heater on stable and level surface. Make sure strong drafts do not blow into front or rear of heater.

3.Plug power cord of heater into a three-prong, grounded extension cord. Extension cord must be at least two meters (six feet) long, CSA listed, and of a proper size.

Extension Cord Wire Size Requirements

Up to 15 meters (50 feet) long, use 18 AWG rated cord.

15.5 to 30.5 meters (51 to 100 feet) long, use 16 AWG rated cord.

31 to 61 meters (101 to 200 feet) long, use 14 AWG rated cord.

4.Plug extension cord into a 120 volt/60 hertz, 3-hole, grounded outlet. Depress start switch for three seconds to start motor and fan. This will force air out front of heater.

Continued

7

102401

Page 7
Image 7
Desa RCLP50A owner manual Ventilation Operation, To Start Heater, Continued, Installation