SERVICE PROCEDURES

SERVICE PROCEDURES

Motor

1.Access ground screw through underside of heater base. Remove ground screw. Disconnect the green motor wire and the green power cord wire from underside of shell (see Figure 6).

2.Remove black and white motor wires from terminal board (see Figure 6).

3.Remove two wire guard screws. Remove wire guard.

4.Set heater on its base. Remove three screws that attach fan guard to heater shell (see Figure 7).

5.Remove motor and fan guard from heater shell. Carefully pull the green, black, and white motor wires from hole in shell (see Figure 7).

6.Use pliers to remove the fan nut from front of motor shaft (see Figure 8).

7.Remove fan. Be careful not to damage the fan blade pitch.

8.Use nut driver to remove three nuts that attach fan guard to motor. Remove fan guard from motor (see Figure 9).

9.Discard old motor.

Continued

!WARNING

Never service heater while it is plugged in, connected to propane supply, operating, or hot. Severe burns and elec- trical shock can occur.

Ground Screw

MotorWire Guard Screws

Wire Guard

Underside of Heater Base

Terminal Board

Figure 6 - Location of Ground Screw and Wire Guard

Fan Guard Screw

Fan Guard

Hole in Shell for Wires

Figure 7 - Removing Motor and Fan Guard from Heater

Fan

Nut

 

Motor Wires

Figure 8 - Removing Fan Nut from

Figure 9 - Removing or Attaching

Motor Shaft

Fan Guard from Motor

11

103911

Page 11
Image 11
Desa RCLP50B owner manual Service Procedures, Motor