Desa RN30BT installation manual Connecting, To Gas Supply, Checking Gas Connections, Continued

Models: RN30BT

1 32
Download 32 pages 16.76 Kb
Page 11
Image 11
CONNECTING

CONNECTING

IMPORTANT: Hold pressure regulator with wrench when connecting it to gas piping and/or fittings.

TO GAS SUPPLY

Continued

Pressure

Regulator

1/2" NPT Pipe Nipple

Note: Burner bracket not shown for clarity

Ground Joint

Union

Heater Cabinet

 

 

 

 

 

Tee Joint

 

 

 

 

 

Test

 

 

 

Reducer

Gauge

 

 

 

 

Bushing to

 

 

 

 

Connection *

 

 

 

1/8" NPT

 

 

 

 

 

 

 

 

 

 

 

 

1/8" NPT

 

 

 

 

 

Plug Tap

Sediment

 

 

 

 

 

 

Tee Joint

 

 

 

 

 

 

 

 

 

 

 

 

Pipe

Trap

 

 

 

 

 

 

 

 

 

 

 

 

Nipple

 

 

 

 

 

 

 

 

Cap

 

 

 

 

 

 

 

 

Manual

Shutoff

Valve *

From

Gas Meter

(4" W.C. to 10.5" W.C.

Pressure)

3" Minimum

CHECKING GAS CONNECTIONS

Figure 11 - Gas Connection

*An A.G.A. design certified manual shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional A.G.A. design certified manual shutoff valve from your dealer. See Accessories, page 25.

!WARNING

Test all gas piping and connections for leaks after installing or servicing. Correct all leaks at once.

!WARNING

Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once.

PRESSURE TESTING GAS SUPPLY PIPING SYSTEM

Test Pressures In Excess Of 1/2 PSIG

1.Disconnect heater and its individual manual shutoff valve from gas supply piping system. Pressures in excess of 1/2 PSIG will damage heater regulator.

2.Cap off open end of gas pipe where manual shutoff valve was connected.

3.Pressurize supply piping system by either using compressed air or opening main gas valve located on or near gas meter.