Desa S36RH, VS36H(1), VS36(1) Firestop Spacers V3600FS-8DM, Penetrating the roof

Models: VS36H(1) S36H VS36(1) S36RH S36 S36R

1 20
Download 20 pages 6.24 Kb
Page 8
Image 8

Venting Installation

Continued

See Detail A

2" Min.

Straps

Detail BStraps

See Detail B

Angle Firestop

 

Existing

Ceiling

Frame

Firestop Spacer

Screws or Staples (Min. of 8)

Figure 10 - Firestop Spacer with Living

Space Above Ceiling

Screws or Staples

Firestop(Min. of 8) Spacer

 

 

Existing

Straps

Straps

Ceiling

 

Frame

Detail A

 

Return Elbow

 

Figure 8 - Ceiling Support Pipe

 

 

12S-8DM

Figure 11 - Firestop Spacer with Attic

 

 

Space Above Ceiling

Screws

B

A

Figure 9 - Elbow Offset

Firestop Spacers (V3600FS-8DM)

Firestop spacers are required at each point where the chimney penetrates a floor space. Their purpose is to establish and maintain the required clearance between the chimney and the combustible materials. When the pipe passes through a framed opening into a living space above, the firestop must be placed onto the ceiling from below as shown in Figure 10.

They also provide complete separation from one floor space to another or attic space as required by most codes. When the double wall pipe passes through a framed opening into an attic space, the firestop must be placed into an attic floor as shown in Figure 11.

Penetrating the roof

To maintain a 1" clearance to the pipe on a roof with a pitch, a rectangular opening must be cut.

1.Determine the center point through which the pipe will penetrate the roof.

2.Determine the center point of the roof. Pitch is the distance the roof drops over a given span, usually 12". A 6/12 pitch means that the roof drops 6" for each 12" one measure horizontally down from the roof rafters.

3.Use the roof opening chart (Figure 12, page 9) to determine the correct opening length and flashing required.

4.Remove the shingles around the opening measured. Cut out this section.

5.Add the next sections of the pipe until the end penetrates the roof line. Check to see that the proper clearances are maintained. Extend chimney by adding sections of double wall pipe until pipe is minimum of 30" above the highest point of the roof cutout. Termination and chimney must extend a minimum of 36" above the highest point where it passes through the roof.

www.desatech.com111026-01C

Page 8
Image 8
Desa S36RH, VS36H(1), VS36(1) installation manual Firestop Spacers V3600FS-8DM, Penetrating the roof

VS36H(1), S36H, VS36(1), S36RH, S36 specifications

The Desa S36R, S36, S36RH, VS36(1), and S36H are notable products in the world of heating solutions, specifically designed to enhance warmth and comfort in various environments. Each model comes with distinct features, technologies, and characteristics aimed at meeting diverse heating needs.

The Desa S36R stands out for its robust design and efficiency. It incorporates state-of-the-art burner technology that ensures a clean and efficient burn, maximizing heat output while minimizing energy consumption. The S36R also features adjustable heat settings, allowing users to tailor the warmth according to their preferences. Its compact size makes it suitable for different settings, whether in residential spaces or workshops.

The Desa S36 model further enhances these attributes with a focus on user-friendly operation. It includes an electronic ignition system, ensuring effortless startup. Additionally, the S36 is equipped with safety features like an automatic shut-off mechanism, which provides peace of mind for users. The durable construction ensures long-lasting use, making it a reliable choice for consistent heating.

For those needing mobility, the Desa S36RH is the ideal option. Its portable design allows for easy transportation, making it suitable for both indoor and outdoor applications. The S36RH emphasizes versatility, coming with multiple fuel options such as propane, which not only diversifies its usability but also accommodates various user preferences.

The VS36(1) model takes innovation a step further with advanced technology integration. It features Wi-Fi connectivity, enabling users to control the heater remotely using a smartphone app. This smart functionality not only adds convenience but also allows for precise temperature management, optimizing energy efficiency. The VS36(1) is characterized by its sleek design, which complements modern home aesthetics while delivering powerful heating performance.

Lastly, the Desa S36H is tailored for high-performance heating in larger spaces. It boasts a powerful output and advanced airflow technology that enhances heat distribution, making it suitable for both residential and commercial applications. The S36H is designed with user comfort in mind, featuring simple controls and a robust design that withstands rigorous use.

In summary, the Desa S36R, S36, S36RH, VS36(1), and S36H models showcase a range of innovative features, efficient technologies, and characteristics suited for various heating requirements. Their focus on safety, efficiency, and user convenience makes them standout choices in the heating solutions market. Whether for home, workshop, or outdoor use, Desa provides reliable options that cater to diverse consumer needs.