OPERATING INSTRUCTIONS

Continued

CAUTION: Do not attempt to slide the viewing hole cover when the main burner is lighting, operating or hot.

3.Set the heat level.

a)Press and turn control knob to the HIGH position, Burner will light immediately.

b)Press and turn control knob to the desired heat level. Note: While in use, burner flame should be mainly blue in appearance with a small amount of yellow.

IMPORTANT: Smoke and odor (not a gas odor) emission may occur in the first 15 minutes of use. Run heater at high setting for at least 15 minutes to eliminate this problem.

WARNING: If you smell gas while in use, immediately press and turn control knob to the "OFF" position to shutdown heater.

STOP

1.Press and turn control knob to the PILOT position. Burner will extinguish but pilot will stay on.

2.To extinguish pilot, press and turn control knob to the OFF position.

3.Turn off gas supply.

4.Do not attempt to relight the heater for 5 minutes after propane/LP cylinder valve has been closed.

RESTART HEATER

1.Turn gas control knob to the OFF position.

2.Wait 5 minutes.

3.Restart following Start procedure.

STORAGE

1.Allow at least 45 minutes for heater to cool down after using.

2.Store heater upright in a sheltered area away from inclement weather and dust.

3.If desired, cover heater after heater has cooled.

4.If heater is not to be used for an extended period of time, disconnect and remove propane/LP gas cylinder and store in accordance with the Standard for Storage and Handling of Liquefied Petroleum Gases, ANSI/INFPA 58.

SERVICING

To assure safety, proper function and longevity of the heater, regular maintenance is required. The frequency of maintenance will depend on the usage of the unit. Review the following concern- ing the criteria for a properly functioning heater. Failing to follow proper, regular maintenance will void warranty.

A hazardous condition may result if a heater is used that has been modified or is not functioning properly. When the heater is working properly:

The flame is contained within the heater.

The flame is essentially blue with perhaps some yellow tipping.

There is no strong disagreeable odor, eye burn- ing or other physical discomfort.

There is no smoke or soot internal or external to the heater.

There are no unplanned or unexplained shut downs of the heater.

The parts lists and wiring diagram show the heater as it was constructed. Do not use a heater which is different from that shown. In this regard, use only the hose, regulator and cylinder connection fitting (called a POL fitting) supplied with the heater. IMPORTANT: Do not use alternates. For this heater, the regulator must be set as shown in Specifications. If there is any uncertainty about the regulator setting, have it checked.

8

www.desatech.com

114144-01A

Page 8
Image 8
Desa SPC-54PHW owner manual Storage, Servicing, Stop, Restart Heater, Set the heat level

SPC-54PHW specifications

Desa SPC-54PHW is an innovative air conditioning solution designed to provide efficient cooling and heating for residential and commercial spaces. This multifunctional unit is characterized by its impressive energy efficiency and user-friendly features, making it a popular choice among consumers looking for comfort and convenience.

One of the standout features of the SPC-54PHW is its inverter technology. This sophisticated system allows the air conditioner to continuously adjust its compressor speed based on real-time cooling demands. As a result, the unit operates at optimal efficiency, significantly reducing energy consumption and minimizing electricity bills. The inverter technology also contributes to a quieter operation, creating a more pleasant environment for occupants.

The SPC-54PHW is equipped with a powerful air purification system that improves indoor air quality. This includes a multi-layer filtration mechanism that captures dust, allergens, and other harmful particles, ensuring that the air circulated within the room is clean and healthy. In addition, the unit features an anti-bacterial filter that inhibits the growth of bacteria and mold, providing an extra layer of protection for users.

Another notable characteristic of the SPC-54PHW is its sleek and modern design. Available in various color options, it seamlessly blends with different interior styles, enhancing the aesthetic appeal of any room. The compact size of the unit also allows for flexible installation in various spaces, including tight corners or smaller areas where traditional units might not fit.

The control system of the SPC-54PHW is designed for ease of use. It comes with a user-friendly remote control that allows occupants to adjust settings conveniently from a distance. Furthermore, the unit is compatible with smart home systems, facilitating integration into existing automation frameworks for enhanced functionality. Users can manage temperature settings, scheduling, and energy consumption with the help of mobile apps, providing control at their fingertips.

Finally, the SPC-54PHW is built with reliability and durability in mind, featuring high-quality components designed to withstand various operational stresses. It comes with an extended warranty, showcasing the manufacturer's confidence in the unit's performance and longevity.

Overall, the Desa SPC-54PHW is a versatile and efficient air conditioning solution that meets diverse cooling and heating needs while ensuring energy savings and user comfort.