STORAGE

TC100VR (Propane) and TC100VRNG (Natural Gas) 100,000 BTU CONSTRUCTION HEATERs

STORAGE

MAINTENANCE CAUTION: Disconnect heater from propane supply tank(s) for Model TC100VR.

1.For Model TC100VR, store propane tank(s) in safe manner. Refer to Chapter 5 of Standard for Storage and Handling of Liquefied Petroleum Gases, ANSI/ NFPA 58 and/or CAN/CGA B149.2. Fol- low all local codes. Always store propane tanks outdoors.

2.Place plastic cover caps over brass fit- tings on inlet connector and hose/regu- lator assembly.

3.Store in a dry, clean, and safe place.

MAINTENANCE

ACCESSORIES WARNING: Never attempt to service heater while it is con- nected to gas supply, operating, or hot. Severe burns can occur.

1.Keep heater clean.

2.Inspect heater before each use. Check connections for leaks. Apply mixture of liquid soap and water to connections. Bubbles forming show a leak that must be corrected. Correct all leaks at once.

3.Inspect hose/regulator assembly, if used, before each use. If hose is highly worn or cut, replace.

4.Have heater inspected yearly by a quali- fied service person.

ACCESSORIES

Purchase these heater accessories and parts from your nearest dealer or service center. If they can not supply an accessory or part, either contact your nearest Parts Central (listed in the separate Authorized Service Center booklet) or call DESA International’s Parts Department at 1-800-972-7879. You can also write to the address listed on the back page of this manual.

Part Number

Description

 

 

LPA4020

Fuel Gas Connector

 

for Propane Tanks

LPA3125

Hose and Regulator

 

Assembly

REPLACEMENT PARTS

Part Number WARNING: Use only original replacement parts. This heater must use design-specific parts. Do not substitute or use generic parts. Improper replacement parts could cause serious or fa- tal injuries. This will also protect your warranty coverage for parts replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized dealers of this product. If they can’t supply original replacement part(s), either contact your nearest Parts Central or call DESA International’s Technical Service Department at 1-800-323-5190.

When calling DESA International, have ready

your name

your address

model and serial numbers of your heater

how heater was malfunctioning

purchase date

In most cases, we will ask you to return the defective part to the factory.

PARTS NOT UNDER

WARRANTY

Contact authorized dealers of this product. If they can’t supply original replacement part(s), either contact your nearest Parts Central or call DESA International’s Parts Department at 1-800-972-7879 for referral information.

When calling DESA International, have ready

model number of your heater

the replacement part number

For more information, visit www.desatech.com