OWNER’S MANUAL
OPERATION
WARNING: Review and un- derstand the warnings in the Safety Information Section, page
2.They are needed to safely op- erate this heater. Follow all local codes when using this heater.
To Stop Heater
1.Tightly close natural gas supply valve.
2.Using a gloved hand, shut off main burner valve. Do this by turning main burner valve handle towards the OFF position until it stops. Note: Arrows on main burner valve handle show direc- tion for ON and OFF.
To Start Heater
1.Follow all installation, ventilation, and safety information.
2.Locate heater on stable and level sur- face. Make sure strong drafts do not blow on heater.
WARNING: Fully close main burner valve before lighting pi- lot. If not, severe burns can oc- cur. Do this by turning valve handle towards the OFF position until it stops.
3.Open natural gas supply valve slowly.
4.Push in and hold automatic control valve button (see Figure 3). Push piezo ignitor button (see Figure 3). You may need to push the piezo ignitor button
5.If pilot light goes out, repeat step 4.
6.When pilot remains lit, fully open main burner valve. Do this by turning main burner valve handle towards the ON position until it stops. Note: Arrows on main burner valve handle show direc- tions for ON and OFF.
To Restart Heater
1.Wait five minutes after stopping heater.
2.Restart heater by following steps un- der To Start Heater.
Piezo Ignitor
Button
Main Burner
Valve Handle
OFF
ON
Automatic
Control
Valve Button
Figure 3 - Main Burner Valve Handle, Automatic Control Valve Button, and Piezo Ignitor Button Locations, With Regulator Installed
104133 | 5 |