Operation
Continued
6.The pilot is located by the main burner and should not require accessing for lighting.
7.Turn gas control knob counterclockwise to PILOT (see Figure 45).
8.Push in gas control knob all the way and hold. Immediately light pilot by repeatedly pressing piezo spark ignitor until a flame appears. Continue to hold for about one
(1)minute after pilot is lit. Release gas control knob and it will pop back. Pilot should remain lit. If it goes out, repeat steps 5 through 8.
• If gas control knob does not pop up when released, stop and immediately call your service technician or gas supplier.
• If pilot will not stay lit after several tries, turn gas control knob to OFF and call your service technician or gas supplier.
9.Turn on all electric power to fireplace.
10.Turn gas control knob counterclockwise to ON.
11.This valve is equipped with a HI/LO fea- ture. Set fireplace input as desired.
12.Close lower louver panel.
13.To leave pilot lit and shut off burners only,
turn control knob clockwise to the PILOT position or set selector switch in the OFF position.
Gas Control Knob Variable Control Knob
Piezo
Ignitor
| PILOT | IH |
F | F |
|
O |
| O |
|
| N |
|
| LO |
Figure 45 - Control Valve
MANUAL LIGHTING
PROCEDURE
1.Remove glass door (see Removing/Re- placing Glass Door, page 25).
2.Follow steps 1 through 8 under Lighting Instructions, page 27.
3.Press gas control knob and light pilot with match.
4.Keep gas control knob pressed in for 30 sec- onds after lighting pilot. After 30 seconds, release gas control knob. Follow steps 9 through 12 under Lighting Instructions.
5.Replace glass door (see Removing/Re- placing Glass Door, page 25).
Optional
REMOTE OPERATION
Note: All remote control accessories must be purchased separately (see Accessories, page 42). Follow instructions included with remote control.
NOTICE: You must light the pilot before using the
After lighting, let pilot flame burn for about one minute. Turn control knob to ON position. Adjust flame adjustment knob anywhere between HI and LO. Slide selector switch to the REMOTE position (see Figure 46).
Note: Burner may light if
IMPORTANT: Do not leave selector switch in the REMOTE or ON position when pilot is not lit. This will drain the battery.
TO TURN OFF GAS
TO APPLIANCE
1.Open lower louver panel.
2.Set selector switch in the OFF position to prevent draining battery.
3.Turn off all electrical power to appliance if service is to be performed.
4.Push in gas control knob slightly and turn
clockwise to OFF.
5.Close lower louver panel.
Blower Control Knob (Optional Accessory)
| Variable Control Knob | |||
OFF | ON |
|
|
|
| N |
|
| |
| O |
| L |
|
|
|
|
| |
| T |
| O | I |
ON OFF REMOTE | O |
| O | H |
L |
|
| ||
| I | F |
| |
|
| P F |
| |
Selector Switch in | Gas Control Knob | |||
in ON Position |
| |||
Remote Position |
|
|
|
|
Figure 46 - Setting Selector Switch, Gas
Control Knob and Variable Control Knob
for Remote Operation
28 | www.desatech.com |