VENTING INSTALLATION INSTRUCTIONS Parts List for Venting Kits and Components FIREPLACE INSTALLATION Check Gas Type Installing Optional Blower Accessories

VENTING INSTALLATION

INSTRUCTIONS

Continued

PARTS LIST FOR VENTING KITS AND

COMPONENTS

DESA (5"/8") Pipe & Vent Kits

Number

Description

P58-6

6" Section Double Wall Pipe, Galvanized

P58-12

12" Section Double Wall Pipe, Galvanized

P58-24

24" Section Double Wall Pipe, Galvanized

P58-36

36" Section Double Wall Pipe, Galvanized

P58-48

48" Section Double Wall Pipe, Galvanized

PA58-712

Adjustable 7"-12" Section Double Wall Pipe,

 

Galvanized

E58-45

45° Elbow, Galvanized

E58-90

90° Elbow, Galvanized

VKG-58

Ground Floor Vent Kit, Galvanized (Includes: 45° El-

 

bow, 7"-12" Adjustable Pipe, Wall Firestop, Horizontal

 

Square Termination, 16 Screws)

VKB-58

Basement Vent Kit, Galvanized (Includes: 45° Elbow,

 

7"-12" Adjustable Pipe, Wall Firestop, Horizontal

 

Square Termination, 4' Pipe, 90° Elbow, 20 Screws)

VKS-58

Snorkel Vent Kit, Galvanized (Includes: 45° Elbow,

 

7"-12" Adjustable Pipe, Wall Firestop, 36" Snorkel

 

Termination, 4' Pipe, 1' Pipe, 90° Elbow, 26 Screws)

VKR-58

Roof Vent Kit, Galvanized (Includes: 45° Elbow, 7"-12"

 

Adjustable Pipe, Flue Restrictor, Vertical High Wind

 

Termination, 2' Pipe, 4' Pipe, Wall Firestop, Storm

 

Collar, Roof Flashing [0/12 - 6/12], 26 Screws)

VKC-58

Corner Vent Kit, Galvanized (Includes 45° Elbow,

 

7"-12" Adjustable Pipe, Wall Firestop, Horizontal

 

Termination, 6" Pipe, 90° Elbow, 18 Screws)

HTK-58

Horizontal Round Termination Kit (Includes Round

 

Termination, Wall Firestop, 45° Elbow)

HT-58

Horizontal Round Termination, Galvanized

HTS-58

Horizontal Square Termination, Galvanized

HTKS-58

Horizontal Square Termination Kit (Includes: Square

 

Termination, Wall Firestop, 45° Elbow)

VT-58

Vertical Round Termination, Galvanized

ST-58-14

14" Snorkel Termination, Galvanized

ST-58-36

36" Snorkel Termination, Galvanized

SC-58

Storm Collar, Galvanized

WF-58

Wall Firestop, Galvanized

RF-58-6

Roof Flashing - 0 to 6/12 Pitch, Galvanized

RF-58-12

Roof Flashing - 6/12 to 12/12 Pitch, Galvanized

VR-58

Vertical Restrictor, Galvanized

S-58

Vinyl Siding Standoff, Galvanized

WS-58

Wall Strap

CS-58

Cathedral Ceiling Support

FP-58

Firestop Plate

SF-58

Stucco Flashing - For use with HTS-58

FIREPLACE INSTALLATION

.CHECK GAS TYPE

Use proper gas type for the fireplace unit you are installing. If you have conflicting gas types, do not install fireplace. See retailer where you purchased the fireplace for proper fireplace according to your gas type or to purchase gas conversion kit (see Accessories, page 36).

INSTALLING OPTIONAL BLOWER

ACCESSORIES

NOTICE: If installing blower in an existing fireplace with gas connections, shut off gas supply and dis- connect heater from gas supply. Contact a qualified service person to do this.

WARNING: If there is a duplex electrical outlet installed in the right side of the bottom of the fireplace base area, be sure that the electrical power to the outlet is turned off before proceeding with blower installation. Failure to do this may result in serious injury.

Model BK Installation

Follow all instructions provided in the blower accessory kit.

1.Attach the power cord to the blower motor by firmly pushing the two female terminals at the end of the power cord onto the two spade terminals on the blower motor (see Figure 25).

2.Attach green ground wire from power cord to blower hous- ing using screw provided (see Figure 25). Tighten screws securely.

3.Place the blower against the lower rear wall of the firebox outer wrapper with the exhaust port directed upward. The blower will fit inside the back opening and be held in position against the back wall by the magnets (see Figure 25).

4.Be certain that all wire terminals are securely attached to ter- minals on blower motor and that the screw retaining the green ground wire is tight.

 

Blower

 

Location

Lower Firebox

 

Cavity

 

Side View

 

Spade Terminals

Magnetic

Strips

 

Green Ground Wire

Screw

 

 

Exhaust Port

Figure 25 - Blower Model BK

 

www.desatech.com

116236-01A

Page 16
Image 16
Desa VC42P SERIES Venting Installation, Fireplace Installation, Check GAS Type, Installing Optional Blower Accessories

VC42N SERIES, VC42P SERIES specifications

Desa VC42P SERIES and VC42N SERIES represent a significant evolution in the realm of heating technology, particularly in the context of modern residential and commercial applications. Designed for efficiency, these products integrate advanced features and innovative technologies that cater to the diverse needs of users seeking reliable heating solutions.

One of the main features of the VC42P SERIES is its high-efficiency performance, achieving exceptional heating output while minimizing energy consumption. This is largely due to its advanced combustion technology, which ensures thorough fuel utilization and significantly reduces emissions. The VC42N SERIES, on the other hand, emphasizes versatile applications, providing a flexible heating option suitable for various environments, including garages, workshops, and large living spaces.

Both series are designed with user-friendly controls, allowing for precise temperature adjustments and easy operation. The intuitive digital thermostat enhances the user experience, enabling personalized comfort settings. In addition, the units come equipped with a built-in timer for programmable heating schedules, promoting energy savings by allowing users to heat spaces only when needed.

Another notable characteristic of the Desa VC42P and VC42N SERIES is their robust construction and durability. Built with high-quality materials, these heaters are designed to withstand everyday wear and tear, ensuring long-lasting performance. This makes them ideal for both residential and commercial use, where reliability is paramount.

The technology behind these heaters also includes safety features such as tip-over protection and overheat sensors, which automatically shut off the unit in unsafe conditions. This not only protects the heater but also contributes to peace of mind for the user, especially in environments with children or pets.

In terms of design, both series boast sleek and modern aesthetics, seamlessly integrating into various interior styles. Their compact size allows for easy placement in different spaces without compromising on heating performance.

Overall, the Desa VC42P SERIES and VC42N SERIES reflect a commitment to innovative heating solutions, blending efficiency, safety, and user-centric design. These heaters not only provide effective warmth but also contribute to reducing environmental impact, making them an excellent choice for environmentally conscious consumers. Whether for daily comfort or specific project needs, these series are engineered to meet and exceed expectations, setting a new standard in heating technology.