Optional Gas Line
Installation
Continued
CAUTION: All gas piping and connections must be tested for leaks after the installation is completed. After ensuring that the gas valve is on, apply soap and water solution to all connections and joints. Bubbles forming show a leak. Correct all leaks at once. DO NOT USE AN OPEN FLAME FOR LEAK TESTING AND DO NOT OPER- ATE ANYAPPLIANCE IF A LEAK IS DETECTED. LEAK TESTING SHOULD BE DONE BYA QUALI- FIED SERVICE PERSON.
WARNING: Do not oper- ate an unvented gas log set in this fireplace with the chimney removed.
If you install a decorative gas appliance (vented gas log), the decorative gas appliance must comply with the Standard for Decorative Gas Appliance for Installation in Solid Fuel Burning Fireplaces, ANS Z21.60, Z21.84 or RG
Outside of |
| Side | |
Fireplace |
| Firebrick | |
Gas | Incoming | Finished | |
Side | |||
Line | 1/2" Black | ||
| |||
Conduit | Iron Pipe |
| |
| Seal |
| |
Repack | Opening |
| |
with |
| ||
Insulation | Refractory |
|
Cement
Provide Enough Threaded
End for Fitting Connection
Figure 19 - Gas Line Installation
WARNING: If the fireplace has been used for wood burning, the firebox and chimney must be cleaned of soot, creosote and ashes by a qualified chimney cleaner. Creosote will ignite if heavily heated.
WARNING: When using a decorative vented gas log, the damper must be removed or permanently locked in the fully open position and the glass doors must be in the fully open position.
Glass Door
Installation
IMPORTANT: Install glass door frame before installing glass door.
Installing Door Frames
1.Remove screws from smoke shelf (see Figure 20).
2.Mount top door frame and secure with screws removed in step 1.
3.Remove center brick by pulling ring handle (see Figure 21, page 12).
4.Remove ash box.
Top Door
Rail
Smoke Shelf
Figure 20 - Installing Top Door Frame
www.desatech.com | 11 |