Venting Installation

Continued

Using ELBOW offsets (30E-12DM)

1.To achieve desired offset, you may install combinations of 12", 18", 24", 36" and 48" length of double wall pipe (see offset chart and Figure 7).

OFFSET

RISE

 

CHIMNEY LENGTH

 

A

B

12"

18"

24"

36"

48"

4 3/8"

16 3/8"

 

ELBOW SET ONLY

 

9 3/4"

25 1/2"

1

 

 

 

 

 

 

12 3/4"

30 3/4"

 

 

1

 

 

 

 

15"

34 3/4"

 

 

 

1

 

 

 

18"

40"

1

 

1

 

 

 

 

21 1/4"

46 1/4"

 

 

 

 

1

 

 

23 3/4"

49 1/4"

 

 

1

1

 

 

 

27 3/4"

56 3/4"

 

 

 

 

 

 

1

30"

60 3/4"

 

 

1

 

1

 

 

33"

66"

1

 

 

 

 

 

1

36"

71"

 

 

1

 

 

 

1

38 1/4"

75"

 

 

 

 

2

 

 

41 1/4"

80 1/4"

1

 

1

 

1

 

 

45"

86 3/4"

 

 

 

 

2

 

 

46 3/4"

89 1/2"

1

 

1

 

 

 

1

51"

97"

 

 

 

 

1

 

1

53 1/4"

101"

 

 

1

 

2

 

 

56 1/4"

106 1/4"

 

 

 

 

 

 

2

59 1/4"

111 1/2"

 

 

1

 

1

 

1

61 3/4"

115 1/2"

1

 

 

 

 

 

2

64 3/4"

120 3/4"

 

 

1

 

 

 

2

68 1/4"

127"

 

 

 

 

2

 

1

70"

130"

1

 

1

 

 

 

2

74 1/4"

137 1/2"

1

 

 

 

2

 

1

76 3/4"

141 1/2"

 

 

1

 

2

 

1

79 3/4"

146 3/4"

 

 

 

 

4

 

 

OFFSET CHART (22-50 FT. SYSTEM HEIGHT)

2.Chimney weight above offset rests on return elbow. Straps must be securely nailed to rafters or joists (see Figure 8, details a and b).

3.Maximum length of pipe between supports (return elbow or 12S-12DM) is 6' of angle run. Maximum of two 6' angle run sections per chimney system (see Figure 7).

4.All pipe connections between the offset and return must be secured with two screws on the outer pipe only (see Figure 9, page 10). Do not penetrate the inner stainless.

See Detail A

2" Min.

Straps

Detail BStraps

See Detail B

Angle Firestop

 

Straps

Straps

Detail A

Return Elbow

Figure 8 - Ceiling Support Pipe

12S-12DM

 

Return

 

Return

 

 

Elbow

 

Elbow

 

Offset

 

Offset

 

Return

 

Elbow

 

 

Elbow

 

 

Elbow

6' Max.

 

 

6' Max.

Ceiling

 

 

 

 

Return

 

 

 

Support Pipe

 

 

Return

 

12S-12DM

6' Max.

Elbow

 

 

 

Elbow

 

 

 

 

 

 

 

 

 

6' Max.

Offset

Offset

 

 

 

 

 

 

Offset

 

Elbow

6' Max. Elbow

6' Max.

 

 

 

 

 

 

Elbow

 

 

 

 

 

 

A

 

B

C

 

 

Figure 7 - Typical Offset Terminations

 

 

www.desatech.com109493-01N

Page 8
Image 8
Desa (V)G42R/50R, (V)G42/50, (V)G42H/50H, (V)G42HR/50HR installation manual Using Elbow offsets 30E-12DM, Elbow SET only

(V)G42H/50H, (V)G42/50, (V)G42R/50R, (V)G42HR/50HR specifications

Desa (V)G42/50, (V)G42HR/50HR, (V)G42R/50R, and (V)G42H/50H represent a series of advanced heating solutions designed to meet varied thermal requirements while ensuring energy efficiency and user comfort. Each model in this range boasts its unique features that cater to specific needs, providing versatility for residential and commercial applications.

The (V)G42/50 series serves as a staple in modern heating technology. With a focus on efficiency and environmental sustainability, these models utilize high-efficiency burners and sophisticated heat exchangers that maximize heat output while minimizing fuel consumption. Their compact design allows for easy installation in limited spaces, making them an ideal choice for both contemporary and traditional settings. Comfort is enhanced through user-friendly digital thermostats that allow for precise temperature control.

Moving to the (V)G42HR/50HR, these units incorporate high-efficiency ratings and variable speed fans to adjust airflow based on heating demand. This adaptability not only increases energy savings but also improves indoor air quality by reducing the accumulation of airborne particulates. The use of high-grade insulation materials ensures minimal heat loss, providing a more consistent indoor temperature.

The (V)G42R/50R models are designed specifically for radiant heating applications. Featuring advanced radiant heat technology, these units distribute warmth evenly across the space, creating a comfortable environment without the drafts often associated with conventional heating systems. The integration of smart home technology allows for remote operation and monitoring, enhancing user convenience.

Lastly, the (V)G42H/50H models are tailored for high-capacity heating needs. These systems are built for larger spaces, offering robust heating capabilities while maintaining energy efficiency. Their construction utilizes durable materials that extend product longevity and reduce the need for frequent maintenance.

In summary, the Desa (V)G series offers a comprehensive lineup of heating solutions with advanced technology and features designed for efficiency, comfort, and adaptability. From standard models to high-capacity and radiant heating systems, each unit addresses unique heating challenges, making them suitable for diverse applications while prioritizing energy conservation and user satisfaction.