Venting Installation

Optional Outside air Kit (Model ak4/ak4f)

The installation of an outside air kit should be per- formed during the rough framing of the fireplace due to the nature of it's location. Outside combus- tion air is accessed through a vented crawl space (AK4F) or through a sidewall (AK4).

CAUTION: Combustion air inlet ducts shall not terminate in attic space.

Secure to Collars with Metal Tape, Screws or Straps (Min. of 1/4" x 20" in size)

Air Inlet

Location

Must Allow

For Bushes

or Snow

 

Air Inlet

 

Eyebrow

Vented Crawl Space

Vent Hood

Required for

(Check Local Codes

Wall Installation

Before Installing in a

 

Vented Crawl Space)

 

Figure 5 - Outside Air Kit

Chimney Pipe

The DESA chimney system consists of 12", 18", 24", 36"' and 48" snap-lock, double-wall pipe segments, planned for maximum adaptability to individual site requirements. Actual lengths gained after fitting overlaps must be taken into consideration (lineal gain) and are given in the lineal gain chart (see Figure 6). Lineal Gain is the actual measurable length of a part after two or more parts are connected. For Canada, use chimney parts designated "HT".

WARNING: The opening in the collar around the chimney at the top of the fireplace must not be obstructed.Neveruseblowninsula- tion to fill the chimney enclosure.

LINEAL GAIN

PART NO.

DESCRIPTION

GAIN (IN)

Georgian

Fireplace

66 1/2"

12-12DM

Pipe Section

10 5/8"

12-12HT

 

 

18-12DM

Pipe Section

16 5/8"

18-12HT

 

 

24-12DM

Pipe Section

23 5/8"

24-12HT

 

 

36-12DM

Pipe Section

34 5/8"

36-12HT

 

 

48-12DM

Pipe Section

46 5/8"

48-12HT

 

 

RLT-12D

Round Termination

7 3/4"*

RLT-12HT

 

 

STL-12D

Square Chase-Top

7" to 15"*

 

with Slip Section

 

*The lineal gain for the terminations is mea- sured to the flue gas outlet height.

15" Galvanized

Outer Pipe

12 3/8"

Hemmed

Stainless

End

 

Inner Pipe

 

Figure 6 - Lineal Gain

Assembly and installation of double wall chimney system

Each double wall chimney section consists of a galvanized outer pipe, a stainless steel inner flue pipe and a wire spacer. The pipe sections must be as- sembled independently as the chimney is installed. When connecting chimney directly to the fireplace, the inner flue pipe section must be installed first with the lanced side up. The outer pipe section can then be installed over the flue pipe section with the hemmed end up. Press down on each pipe section until the lances securely engage the hem on the fire- place starter. The wire will assure the proper spacing between the inner and outer pipe sections.

Continue to assemble chimney sections as outlined above, making sure that both the inner and outer pipe sections are locked together. When install- ing double wall snap-lock chimney together, it is important to assure the joint between the chimney sections is locked. Check by pulling chimney upward after locking. The chimney will not come apart if properly locked. It is not necessary to add screws to keep the chimney together (exception, see Figure 9, page 10).

www.desatech.com112435-01M

Page 8
Image 8
Desa (V)gM42h, (V)gM50h, (V)gM36h Venting Installation, Optional Outside air Kit Model ak4/ak4f, Chimney Pipe

(V)gM36, (V)gM36h, (V)gM42h, (V)gM42, (V)gM50h specifications

Desa (V)gM36h, (V)gM42h, (V)gM42, (V)gM50h, and (V)gM50 are advanced models of the Desa family, showcasing a blend of innovative technologies and robust characteristics designed for versatile functionality in various environments. These models gain recognition for their performance in both residential and commercial applications, each tailored to meet specific user needs.

The (V)gM36h model stands out with its compact design yet powerful capability. It features high energy efficiency, which contributes to lower operational costs while maintaining exceptional performance. The model operates with an advanced control system allowing precise temperature adjustment, ensuring user comfort and energy optimization.

Meanwhile, the (V)gM42h enhances the features of the 36h model with added functionality. Its integration of smart technology allows remote management through mobile applications, facilitating ease of use. The (V)gM42h comes equipped with a self-diagnosis feature that monitors system performance in real-time, alerting the user to potential issues before they become significant problems.

The (V)gM42 is designed with sustainability in mind. It utilizes eco-friendly refrigerants that comply with environmental regulations while delivering optimal cooling and heating performance. This model is also noted for its noise reduction technology, making it an ideal choice for residential spaces where tranquility is paramount.

On the higher end, the (V)gM50h model combines enhanced capacity with advanced features that cater to larger spaces. It integrates variable-speed technology, allowing the system to adjust its output dynamically, which enhances energy efficiency and comfort. The (V)gM50h also includes a robust filtration system that improves indoor air quality by minimizing pollutants.

Finally, the (V)gM50 serves as a flagship offering, combining all the notable advantages of its predecessors with even greater performance efficiency and user-friendly features. It is engineered for heavy-duty performance, making it suitable for demanding commercial applications while still maintaining a user-centric approach for ease of operation.

Collectively, the Desa models represent a significant advancement in temperature control technology, combining energy efficiency, user-friendly features, and environmental considerations to meet the modern demands of users across various sectors.