SAFETY INFORMATION PRODUCT IDENTIFICATION LOCAL CODES

3

SAFETY INFORMATION

Continued

5.

This fireplace reaches high temperatures. Keep children and

 

adults away from hot surfaces to avoid burns or clothing igni-

 

tion. Fireplace will remain hot for a time after shutdown. Allow

 

surfaces to cool before touching.

6.

Carefully supervise young children when they are in the room

 

with fireplace.

7.

Do not modify this fireplace under any circumstances. Any

 

parts removed for servicing must be replaced prior to operating

 

fireplace.

8.

Turn fireplace off and let cool before servicing, installing or

 

repairing. Only a qualified service person should install, service

 

or repair this fireplace. Have fireplace inspected annually by a

 

qualified service person.

9.

You must keep control compartments, burners and circulating

 

air passages clean. More frequent cleaning may be needed due

 

to excessive lint and dust from carpeting, bedding material, etc.

PRODUCT IDENTIFICATION

Upper Louver

 

Panel

Flue Collar

 

Nailing

 

Flange

 

Glass

 

Door

 

Assembly

Log

 

Lava

Set

Rock

 

 

Turn off the gas valve and pilot light before cleaning fireplace.

10.

Have venting system inspected annually by a qualified service

 

person. If needed, have venting system cleaned or repaired. See

 

Cleaning and Maintenance, page 25.

11. Keep the area around your fireplace clear of combustible ma-

 

terials, gasoline and other flammable vapor and liquids. Do

 

not run fireplace where these are used or stored. Do not place

 

items such as clothing or decorations on or around fireplace.

12.

Do not use this fireplace to cook food or burn paper or other

Lower

Louver

Panel

Electronic

Control Valve Glowing

Embers

Burner Assembly

Andiron

Assembly

Switch Bracket for Optional Remote and Blower

 

objects.

13.

Do not use any solid fuels (wood, coal, paper, cardboard, etc.)

 

in this fireplace. Use only the gas type indicated on fireplace

 

nameplate.

14.

This appliance, when installed, must be electrically grounded

 

in accordance with local codes or, in the absence of local

 

codes, with the National Electrical Code, ANSI/NFPA 70 or

 

the Canadian Electrical Code, CSA C22.1.

15.

Do not use fireplace if any part has been exposed to or under

 

water. Immediately call a qualified service person to arrange

 

for replacement of the unit.

16.

Do not operate fireplace if any log is broken.

17.

Do not use a blower insert, heat exchanger insert or other ac-

 

cessory not approved for use with this fireplace.

18.

Do not operate fireplace with glass door removed, cracked or

 

broken.

19.

Provide adequate clearances around air openings.

Figure 1 - Direct-Vent Fireplace with Electronic Ignition

LOCAL CODES

Install and use fireplace with care. Follow all local codes. In the absence to local codes, use the current National Fuel Gas Code ANSI Z223.1/NFPA 54* (USA) or the current CSA-B149.1 Instal- lation Code (Canada).

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

116238-01C

www.desatech.com

Page 3
Image 3
Desa (V)KC36PE installation manual Product Identification, Local Codes

(V)KC36PE specifications

The Desa (V)KC36PE is a remarkable heating and air conditioning solution designed for both residential and commercial applications. At its core, the unit combines contemporary technology with user-friendly features, making it a popular choice among homeowners and business owners alike.

One of the standout characteristics of the Desa (V)KC36PE is its energy efficiency. The unit operates using advanced refrigerant technologies that allow for optimal cooling and heating while consuming less power. This efficiency not only lowers energy bills but also contributes to a smaller carbon footprint, aligning with global sustainability goals.

The Desa (V)KC36PE features a powerful inverter compressor. This technology adjusts the speed of the compressor to maintain the desired temperature without frequent on-and-off cycles, resulting in quieter operation and enhanced durability. The inverter system also minimizes temperature fluctuations, ensuring a consistent indoor climate.

Ease of use is another essential aspect of the Desa (V)KC36PE. The unit comes equipped with a sleek, intuitive control panel, allowing users to adjust settings effortlessly. Many models also include a remote control and smart connectivity options, enabling users to monitor and manage their heating and cooling systems through mobile applications.

In terms of design, the Desa (V)KC36PE boasts a modern aesthetic that can seamlessly blend into various interior styles. Its compact size makes it suitable for installation in tight spaces without sacrificing performance. Additionally, the unit includes advanced air filtration systems that improve indoor air quality by removing dust, allergens, and other pollutants, ensuring a healthy living environment.

The unit is manufactured with durability in mind, employing high-quality materials that withstand the rigors of daily use. Its weather-resistant casing makes it suitable for various climates, ensuring performance stability throughout the seasons.

Overall, the Desa (V)KC36PE stands out due to its energy-efficient operation, innovative technology, user-friendly features, and robust design. Whether for residential or commercial use, it offers an effective solution for maintaining comfortable indoor environments all year round, highlighting Desa's commitment to quality and customer satisfaction.