Desa VMH26TNB Checking GAS Connections, Pressure Testing Gas Supply Piping System

Models: VMH26TNB

1 28
Download 28 pages 20 Kb
Page 16
Image 16

® VMH26TNB

COMPACT CLASSIC HEARTH FIREPLACE

INSTALLATION

Continued

CHECKING GAS

CONNECTIONS

WARNING: Test all gas pip- ing and connections for leaks after installing or servicing. Cor- rect all leaks at once.

WARNING: Never use an open flame to check for a leak. Apply a noncorrosive leak detection fluid to all joints. Bubbles forming show a leak. Correct all leaks at once.

Pressure Testing Gas Supply Piping System

Test Pressures In Excess Of 1/2 PSIG (3.5 kPa)

Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa)

1.Close equipment shutoff valve (see Fig- ure 26).

2.Pressurize supply piping system by either using compressed air or opening main gas valve located on or near gas meter.

3.Check all joints from gas meter to equipment shutoff valve (see Figure 27). Apply a noncorrosive leak detec- tion fluid to gas joints. Bubbles form- ing show a leak.

4.Correct all leaks at once.

Equipment

Open

Shutoff

 

Valve

 

 

Closed

 

PO

Figure 26 - Equipment Shutoff Valve

Pressure Testing Fireplace Gas Connections

1.Open equipment shutoff valve (see Fig- ure 26).

2.Open main gas valve located on or near gas meter.

3.Make sure control knob of fireplace is in the OFF position.

4.Check all joints from equipment shutoff valve to thermostat gas valve (see Fig- ure 27). Apply a noncorrosive leak de- tection fluid to gas joints. Bubbles forming show a leak.

5.Correct all leaks at once.

6.Light fireplace (see Operating Fire- place, pages 17 and 18). Check all other internal joints for leaks.

7.Turn off fireplace (see To Turn Off Gas to Appliance, page 18).

8.Replace front panel.

1.Disconnect appliance with its appliance main gas valve (control valve) and equip- ment shutoff valve from gas supply pip- ing system. Pressures in excess of 1/2 psig will damage fireplace regulator.

2.Cap off open end of gas pipe where equipment shutoff valve was connected.

3.Pressurize supply piping system by either using compressed air or opening main gas valve located on or near gas meter.

4.Check all joints of gas supply piping system. Apply a noncorrosive leak de- tection fluid to gas joints. Bubbles forming show a leak.

5.Correct all leaks at once.

6.Reconnect heater and equipment shutoff valve to gas supply. Check re- connected fittings for leaks.

Equipment

Shutoff

Valve

Gas Meter

Figure 27 - Checking Gas Joints

16

107029

Page 16
Image 16
Desa VMH26TNB installation manual Checking GAS Connections, Pressure Testing Gas Supply Piping System

VMH26TNB specifications

The Desa VMH26TNB is a versatile and innovative heating appliance designed to meet the demands of modern home environments. This unit combines cutting-edge technology with practical features to provide efficient heating solutions for various spaces.

One of the key highlights of the VMH26TNB is its impressive heat output. With a powerful capacity, it can effectively heat large areas, making it ideal for living rooms, open-concept spaces, or even commercial settings. Its heating efficiency is bolstered by the incorporation of advanced thermal conduction materials that ensure maximum warmth with minimal energy consumption.

Another notable feature of the Desa VMH26TNB is its user-friendly control system. Equipped with a digital thermostat, this model allows users to set their desired temperature with precision. The intuitive interface provides real-time feedback, enabling users to monitor their energy usage and adjust settings accordingly for optimal comfort.

The VMH26TNB is also designed with safety in mind. It includes multiple safety features, such as overheat protection and a tip-over switch that automatically shuts off the unit in case it tips over. These features are crucial in preventing accidents, making this heater a reliable addition to any home.

In terms of technology, the Desa VMH26TNB stands out with its energy-efficient operation, which is compliant with modern energy standards. It uses a combination of infrared and convection heating methods that distribute warmth evenly throughout the room. This dual heating technology not only enhances comfort but also reduces energy costs.

Additionally, the unit is designed with aesthetics in mind. Its sleek and contemporary design allows it to blend seamlessly with various interior styles, making it not just a functional appliance but also an attractive element of home decor.

Lastly, ease of maintenance is another characteristic that enhances the desirability of the VMH26TNB. Its filter is easily accessible for cleaning, ensuring that the device operates at peak performance over time.

In summary, the Desa VMH26TNB is a powerful, efficient, and safe heating solution that caters to modern heating needs while providing style and convenience. Its blend of advanced technology and thoughtful design makes it an excellent choice for both residential and commercial applications.