Desa VN6D installation manual Installation, Continued, Connecting To Gas Supply, Gas Connection

Models: VN6D

1 20
Download 20 pages 9.77 Kb
Page 9
Image 9
CONNECTING TO GAS SUPPLY

OWNER’S MANUAL

INSTALLATION

Continued

CONNECTING TO GAS SUPPLY

Figure 12 - Gas Connection WARNING: This appliance re- quires a 3/8" NPT (National Pipe Thread) inlet connection to the pressure regulator.

Manual backgroundWARNING: A qualified service person must connect heater to gas supply. Follow all local codes.

IMPORTANT: Install an equipment shutoff valve in an accessible location. The equip- ment shutoff valve is for turning on or shutting off the gas to the appliance.

Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves.

Manual backgroundCAUTION: Use pipe joint seal- ant that is resistant to liquid pe- troleum (LP) gas.

Install sediment trap in supply line as shown in Figure 12. Locate sediment trap where it is within reach for cleaning. Locate sedi- ment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into heater controls. If sediment trap is not installed or is installed wrong, heater may not run properly.

IMPORTANT: Hold pressure regulator with wrench when connecting it to gas pip- ing and/or fittings.

Manual background WARNING: Never connect heater to private (non-utility) gas wells. This gas is commonly known as wellhead gas.

IMPORTANT: Check gas line pressure be- fore connecting heater to gas line. Gas line pressure must be no greater than 14 inches of water. If gas line pressure is higher, heater regulator damage could occur.

3/8" NPT Pipe Nipple

Pressure

Regulator

Heater

Cabinet

Ground Joint

Union

Manual background CAUTION: Use only new, black iron or steel pipe. Inter- nally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe 3/8" diameter or greater to allow proper gas volume to heater. If pipe is too small, undue loss of pressure will occur.

Installation must include a equipment shutoff valve, ground joint union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be up- stream from heater (see Figure 12). An appliance main gas valve (equipment shutoff

Equipment

Shutoff

Valve *

From

Gas Meter (5" W.C. to 10.5" W.C. Pressure)

3" Minimum

Figure 12 - Gas Connection

Tee Joint

 

 

 

 

 

 

 

 

Reducer

 

Test

Bushing to

 

 

Gauge

1/8" NPT

 

 

Connection *

 

 

 

 

1/8" NPT

 

 

Plug Tap

 

 

 

 

 

 

Tee

 

 

 

Joint

 

 

Pipe

 

Sediment

 

Trap

Nipple

 

 

Cap

 

 

 

 

 

 

valve) shall be provided in an accessible location for turning on or shutting off the gas to the appliance.

*A CSA/AGA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional CSA/AGA design-certified equipment shutoff valve from your dealer. See Accessory, page 18.

Continued

104274

9

Page 9
Image 9
Desa VN6D installation manual Installation, Continued, Connecting To Gas Supply, Gas Connection