12

OPERATING HEATER (Manual Control Infrared Models)

For Your Safety Read Before Lighting (Cont.)

Lighting Instructions

To Select Heating Level

To Turn Off Gas To Appliance

OPERATING HEATER

Continued

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service techni- cian or gas supplier. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING

INSTRUCTIONS

1.STOP! Read the safety information page 11, column 2.

2.Make sure equipment shutoff valve is fully open.

3.Turn control knob clockwise to the OFF position.

4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Fol- low “B” in the safety information, page 11, column 2. If you don’t smell gas, go to the next step.

5.Press in control knob, and turn counterclockwise to pilot position. Keep control knob pressed for five seconds.

Note: You may be running this heater for the first time after hooking up to gas supply. If so, the control knob may need to be pressed in for 30 seconds or more. This will al- low air to bleed from the gas system.

If control knob does not pop up when released, contact a qualified service person or gas supplier for repairs.

6.With control knob pressed in, push down and release ignitor button. This will light pilot. The pilot is attached to the front of burner. If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not light, refer to Troubleshooting, pages 17 through 19. Also contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match, see Manual Lighting Procedure, page 13.

7.Keep control knob pressed in for 10 seconds after lighting pilot. After 10 seconds, release control knob.

Note: If pilot goes out, repeat steps 3 through 7.

Piezo Ignitor

 

Ignitor Electrode

 

Thermocouple

Pilot

Button

Control Knob

 

 

 

 

Burner

 

PILOT

OFF

 

 

 

 

 

 

IGNITOR

LOW

 

 

 

 

 

HIGH

 

 

TO SELECT

HEATING LEVEL

WARNING: When running heater, set control knob at LOW or HIGH locked positions for double burner heater, or ON position for single burner heater.. Never set control knob between locked positions. Poor combustion and higher levels of carbon monox- ide may result.

CAUTION: Do not try to adjust heating levels by using the equipment shutoff valve.

Slightly press in control knob and turn

counterclockwise to the LOW or HIGH positions for double burner heater, or ON position for single burner heater.

IMPORTANT: Release downward pressure while turning con- trol knob. Control knob will lock at the desired position.

Control

Double

Control

Single

Knobs

Burners

Knob

Burner

 

 

OFF

 

 

 

PILOT

 

 

 

ON

 

 

 

OFF

 

Figure 21 - Burner Patterns

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

Turn control knob clockwise to the OFF position.

Shutting Off Burner Only (pilot stays lit)

Figure 19 - Control Knob In

Figure 20 - Pilot, Infrared Turn control knob clockwise to the PILOT position.

The OFF Position

Heaters

For morevisit www..com

110720-01B

Page 12
Image 12
Desa VP10A VN10TA, VP10TA VN6D installation manual To Select Heating Level, Burner Patterns

VP10TA VN6D, VP10A VN10TA specifications

Desa VP10A, VN10TA, VP10TA, and VN6D are noteworthy models in the realm of cutting-edge technology, designed to cater to modern industrial and consumer needs. Each model boasts unique features and characteristics, making them suitable for various applications.

The Desa VP10A is recognized for its robust performance and high reliability. It typically includes advanced air filtration systems that ensure optimal air quality while maintaining efficient operation. Its energy-efficient design minimizes power consumption without compromising performance, making it an environmentally friendly choice. This model often incorporates user-friendly controls, allowing for effortless adjustments and monitoring of operations.

Moving on to the VN10TA, this unit excels in terms of versatility and adaptability. It is built with a modular design, allowing users to customize the configuration based on specific requirements. This feature enhances its applicability across different sectors, such as manufacturing and logistics. The VN10TA also integrates sophisticated connectivity options, enabling seamless integration with existing systems while providing data analytics capabilities for better operational insights.

The VP10TA model places a strong emphasis on performance efficiency. It includes state-of-the-art technologies such as variable speed drives, which optimize energy use and enhance overall system performance. Moreover, the VP10TA is often equipped with smart sensors that monitor operational parameters in real time, ensuring maximum efficiency and longevity of the unit.

Lastly, the VN6D model stands out with its compact design, perfect for environments with space constraints. Despite its smaller footprint, the VN6D does not compromise on power or efficiency. The unit is designed for quick installation and maintenance, streamlining processes in busy settings. Additionally, it incorporates noise-reduction technologies, making it an excellent choice for applications in noise-sensitive areas.

All models feature high-quality construction materials, ensuring durability and resistance to wear and tear, which is critical in demanding environments. The combination of innovative features and superior technologies in the Desa VP10A, VN10TA, VP10TA, and VN6D makes them valuable assets for any industrial or commercial setup, effectively catering to the intricate demands of today’s economy. Their exceptional performance, adaptability, and efficiency are testaments to Desa's commitment to quality and innovation in technology.