Desa installation manual Service Publications Hints, VP1600IT VP2200IT, VP1600C VP2600C

Models: VP1600C VP2200IT VP1600IT VP2600C

1 40
Download 40 pages 13.74 Kb
Page 30
Image 30

SPECIFICATIONS

SERVICE PUBLICATIONS

SERVICE

HINTS

 

VP1600IT

VP2200IT

BTU (Variable)

6,000-16,000

6,500-22,000

Type Gas

Propane Only

Propane Only

Ignition

Piezo

Piezo

Pressure Regulator Setting

8" W.C.

8" W.C.

Inlet Gas Pressure (in. of water)

 

Maximum

14"

14"

Minimum

11"

11"

Dimensions, Inches (H x W x D)

 

Heater

23.5 x 18.5 x 8

23.5 x 25.9 x 8

Carton

25.8 x 21.3 x 10.1

25.8 x 28.7 x 10.1

Weight (pounds)

 

 

Heater

24

32

Shipping

29

38

 

VP1600C

VP2600C

BTU (Variable)

6,000/11,000/16,000

6,000/16,000/26,000

Type Gas

Propane Only

Propane Only

Ignition

Piezo

Piezo

Pressure Regulator Setting

8" W.C.

8" W.C.

Inlet Gas Pressure (in. of water)

 

Maximum

14"

14"

Minimum

11"

11"

Dimensions, Inches (H x W x D)

 

Heater

23.5 x 18.5 x 8

23.5 x 25.9 x 8

Carton

25.8 x 21.3 x 10.1

25.8 x 28.7 x 10.1

Weight (pounds)

 

 

Heater

22

30

Shipping

27

36

You can purchase a service manual from the address listed on the back page of this manual. Send a check for $5.00 payable to DESA International.

When gas pressure is too low

pilot will not stay lit

burner(s) will have delayed ignition

heater will not produce specified heat

propane gas supply may be low

When gas quality is bad

pilot will not stay lit

burner(s) will produce flames and soot

heater will backfire when lit

You may feel your gas pressure is too low or gas quality is bad. If so, contact your local propane gas supplier.

30