Desa VTDMV18NA, VTDMV24PA, VTDMV24NA Continued, Pilot Flame Pattern, On/Off Series Model Ghrcb

Models: VTDMV18PA VTDMV24NA VTDMV24PA VTDMV18NA

1 20
Download 20 pages 38.64 Kb
Page 11
Image 11
PILOT FLAME PATTERN

OPERATING APPLIANCE

Continued

NOTICE: You must light the pilot before using the hand-held re- mote control unit. See Lighting Instructions on page 10.

After lighting, let pilot flame burn for about one minute. Turn control knob to ON posi- tion. Adjust flame adjustment knob anywhere between HI and LO. Flip AUTO/OFF/ON switch to AUTO. Slide the selector switch to the REMOTE position (see Figure 13). Note: The burner may light if hand-held remote was on when selector switch was last turned off. You can now turn the burner on and off with the hand-held remote control unit.

IMPORTANT: Do not leave the selector switch in the REMOTE or ON position when the pilot is not lit. This will drain the battery.

Control Knob

•see Troubleshooting, page 13 REMOTE

OFF

ON

INSPECTING BURNERS

Check pilot flame pattern and burner flame pat- terns often.

PILOT FLAME PATTERN

You can view the pilot light through the pilot viewing hole on the pilot bracket. This is located under the front grate bar on the right side of the log set.

Figure 15 shows a correct pilot flame pattern. Figure 16 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the ther- mocouple. This will cause the thermocouple to cool. When the thermocouple cools, the appliance will shut down.

If pilot flame pattern is incorrect, as shown in Figure 16

turn appliance off (see To Turn Off Gas to Appliance, page 10)

see Troubleshooting, page 13

Note: The pilot flame on natural gas units will have a slight curve but flames should be blue and have no yellow or orange color.

Thermocouple

 

 

Flame

Selector Switch in

Piezo

 

REMOTE Position

 

Adjustment

 

 

Ignitor

 

Knob

 

 

 

 

Figure 13 - Setting the Selector Switch,

Control Knob and Flame Adjustment

 

Knob for Remote Operation

ON/OFF SERIES (MODEL GHRCB)

Hold the control button on the hand-held remote

until burner turns on. Hold the control button

again until burner turns off (see Figure 14).

To Lock press both buttons on hand-held

remote control until light stops flashing. Hand-

held remote control is now locked. If the fire is

on it will be turned off automatically. In the

locked state, the light will not light up when

any button is pressed.

 

To Unlock press both buttons together on hand-

held remote control until the light stops flashing.

The hand-held remote is now unlocked.

 

 

 

Control Button

 

 

 

Turns Burner

 

 

 

On and Off

Figure 14 - On/Off Hand-Held Remote

 

 

Control Unit (GHRCB)

Figure 15 - Correct Pilot Flame Pattern (Your pilot may vary from pilots shown)

Thermocouple

Figure 16 - Incorrect Pilot Flame Pattern (Your pilot may vary from pilots shown)

BURNER FLAME PATTERN Figure 17 shows correct burner flame pattern.

NOTICE: Do not mistake orange flames with yellow tipping. Dirt or other fine particles are burned by appliance, causing brief patches of orange flame.

Yellow Flames ON/OFF SERIES (MODEL GHRCB) with Orange Figure 16 - Correct Burner Flame PatternManual background Streaks

Figure 16 - Correct Burner Flame Pattern

114926-01B

www.desatech.com

11

Page 11
Image 11
Desa VTDMV18NA, VTDMV24PA, VTDMV24NA Continued, Pilot Flame Pattern, On/Off Series Model Ghrcb, see Troubleshooting, page