FIREPLACE INSTALLATION

Installing Optional Blower Accessory (Cont.)

17

FIREPLACE INSTALLATION

Continued

4.Be certain that all wire terminals are securely attached to ter- minals on blower motor and that the screw retaining the green ground wire is tight.

5.Mount speed control box to switch bracket by placing the plastic control shaft forward through the opening in the switch bracket (see Figure 26).

6.While supporting speed control, secure control shaft with lock nut by pushing and turning lock nut with pliers clockwise until it is tight against front panel. Place control knob provided on shaft.

7.Turn on power to duplex outlet if previously turned off per the warning in column 2, page 16.

8.Plug in blower power cord.

a.If your firebox is installed as a freestanding unit with an accessory mantel, determine whether the power cord will exit the left side or the right side of the firebox. Route power cord through exit hole and plug the power cord into a wall receptacle near the firebox.

b.If your firebox installation is recessed and/or pre-wired, plug the power cord into the duplex outlet provided. Refer to your firebox owner’s manual for instructions on wiring the duplex outlet.

CAUTION: Never touch the blower wheel while in operation.

9.Check to make sure that the power cord is completely clear of the blower wheel and that there are no other foreign objects in blower wheel. Turn blower on and check for operation. Turn blower off by turning knob fully counterclockwise before continuing.

10.Peel off the backing paper and stick the supplied wiring dia- gram decal on the firebox bottom approximately 12" in front of the blower (see Figure 27).

Switch

Speed Control

Bracket

Blower

 

 

Plug-In

Control

Knob

Locknut

Control

Duplex Outlet

 

Shaft

 

(Located underneath

 

 

 

 

firebox floor against

 

 

lower right outside wall)

Figure 26 - Attaching Speed Control to Firebox

Wiring Diagram Decal

12" in Front of Blower

Figure 27 - Location of Wiring Diagram Decal (Model May Vary From Illustration)

Lower Firebox

Cavity

Side View

Blower

Location

Magnetic Strips

Spade Terminals

Exhaust

 

Port

Green

Ground Wire

Figure 25 - Blower Model BK

Screw

For morevisit www..com

111253-01A

Page 17
Image 17
Desa (V)V36EPA(1), (V)V36ENA(1) installation manual Attaching Speed Control to Firebox