Desa Tech CGN20TA Checking Gas Connections, Owner’S Manual, Test Pressures In Excess Of 1/2 PSIG

Models: CGN20TA

1 24
Download 24 pages 27.88 Kb
Page 11
Image 11
CHECKING GAS CONNECTIONS

OWNER’S MANUAL

CHECKING GAS CONNECTIONS

PRESSURE TESTING GAS SUPPLY PIPING SYSTEM WARNING: Test all gas pip- ing and connections for leaks after installation or servicing. Correct all leaks at once.

Test Pressures In Excess Of 1/2WARNING: Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once.

PRESSURE TESTING GAS SUPPLY PIPING SYSTEM

Test Pressures In Excess Of 1/2

PSIG

1.Disconnect heater and its individual manual shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig will damage heater regulator.

2.Cap off open end of gas pipe where manual shutoff valve was connected.

3.Pressurize supply piping system by ei- ther using compressed air or

opening main gas valve located on or near gas meter.

4.Check all joints of gas supply piping system. Apply mixture of liquid soap and water to gas joints. Bubbles form- ing show a leak.

5.Correct all leaks at once.

Test Pressures Equal To or Less Than 1/2 PSIG

1.Close manual shutoff valve (see Fig- ure 14).

2.Pressurize supply piping system by ei- ther using compressed air or opening main gas valve located on or near gas meter.

3.Check all joints from gas meter to manual shutoff valve (see Figure 15). Apply mixture of liquid soap and wa- ter to gas joints. Bubbles forming show a leak.

4.Correct all leaks at once.

Manual

Open

Shutoff

 

Valve

 

Closed

Figure 14 - Manual Shutoff Valve

Gas Meter

PRESSURE TESTING

HEATER GAS

CONNECTIONS

1.Open manual shutoff valve (see Fig- ure 14).

2.Open main gas valve located on or near gas meter.

3.Make sure control knob of heater is in the OFF position.

4.Check all joints from manual shutoff valve to thermostat gas valve (see Fig- ure 15). Apply mixture of liquid soap and water to gas joints. Bubbles form- ing show a leak.

5.Correct all leaks at once.

6.Light heater (see Operating Heater, pages 12 and 13). Check the rest of the internal joints for leaks.

7.Turn off heater (see To Turn Off Gas to Appliance, page 12).

8.Replace front panel.

Thermostat Gas Valve

Manual

Shutoff

Valve

Figure 15 - Checking Gas Joints

104190

11

Page 11
Image 11
Desa Tech CGN20TA installation manual Checking Gas Connections, Owner’S Manual, Pressure Testing Gas Supply Piping System