Desa Tech PC4670LP Operating Appliance, Installation, Continued, Pressure Testing Appliance Gas

Models: PC3460LP

1 14
Download 14 pages 35.84 Kb
Page 7
Image 7
OPERATING

OWNER’S MANUAL

INSTALLATION

(Continued)

2.Pressurize supply piping system by ei- ther using compressed air or opening propane/LP supply tank valve.

3.Check all joints from propane/LP sup- ply tank to equipment shutoff valve (see Figure 7). Apply mixture of liquid soap and water to gas joints. Bubbles form- ing show a leak.

4.Correct all leaks at once.

Pressure Testing Appliance Gas CAUTION: Place lava rock carefully. Be careful not to dam- age the burner, ignitor electrode, or thermocouple when adding the lava rock.

Place the six refractory logs on top of the lava rock. The arrangement is left to your personal preference. Try different place- ments to achieve your desired flame pattern.

Note: Sooting on the logs is natural. You may clean with a soft bristle brush.

OPERATING

APPLIANCE

FOR YOUR SAFETY

READ BEFORE

LIGHTING

Connections (Fixed Piping WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result caus- ing property damage, personal

Pressure Testing Appliance Gas

Connections (Fixed Piping

System Only)

1.Open equipment shutoff valve (see Fig- ure 6, page 6).

2.Open propane/LP supply tank valve.

3.Check all joints from equipment shutoff valve to supply hose. Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak.

4.Correct all leaks at once.

Propane/LP Supply Tank (100 lb. or larger)

Equipment Manual background

Shutoff

Valve

Manual background WARNING: Allow logs and lava rock to cool completely be- fore handling or rearranging logs.

Manual background WARNING: Solid fuels shall not be burned in this gas fireplace.

BATTERY INSTALLATION

Your Comfort Glow Patio Fire uses an elec- tronic ignitor which requires one AA alka- line battery (not included). The battery com- partment is located in the ignitor module behind the ignitor button.

To install the battery into the ignitor:

1.Locate the ignitor button on the con- trol panel (see Figure 8).

2.Rotate the ignitor button counterclock- wise to remove.

injury, or loss of life.

Manual background WARNING: Do not use this appliance if any gas control parts have been under water. Immedi- ately call a qualified service per- son to inspect the Patio Fire and replace any part of the control system and any gas control that has been under water.

Manual background WARNING: All gas burning appliances may produce smoke, soot, or carbon monoxide during operation. These fumes can be harmful if the appliance is used anywhere other than in an open air, fully-vented area.

BEFORE LIGHTING smell all around the

3. Install a fresh AA alkaline battery into

Control Valvethe ignitor module, positive terminal first. Location

4. Replace button by rotating clockwise.

Figure 7 - Checking Gas JointsTighten finger tight. Do not over- tighten.

appliance area for gas. Be sure to smell next to the ground because some gas is heavier than air and will settle on the ground.

WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.

SETUP

Your Comfort Glow Patio Fire is designed to operate with lava rock piled in and around the burner, and refractory logs placed on top of the lava rock.

Carefully pour supplied lava rock into basin to cover the burner. Be sure that the burner and burner ports are covered completely by lava rock to better disperse the flame and to create a more natural looking fire.

Note: Your fire pit may be lighted using a match (see Lighting Instructions, page 8).

Ignitor Button

Figure 8 - Control Panel

• Do not touch any electric switch; do

 

not use any phone in your building.

Immediately call your gas supplier

 

from a neighbor’s phone. Follow the

 

gas supplier’s instructions.

If you cannot reach your gas sup-

 

plier, call the fire department.

Continued

107497

7

For more information, visit www.desatech.com

Page 7
Image 7
Desa Tech PC4670LP, PC3460LP Operating Appliance, Installation, Continued, Pressure Testing Appliance Gas