MAINTENANCE PARTS LIST
Contact the DeVilbiss Air Power Company Customer Service Department
1-800-888-2468 Ext.2
For Authorized Service Center nearest you
Part No. | Qty. | Description |
|
|
|
1 | Air Filter | |
1 | Fuel Line | |
2 | Fuel Line Clamps | |
1 | Gas Tank | |
4 | Gas Tank Washers | |
4 | Gas Tank Screws | |
1 | Gas Gap | |
2 | Isolators | |
2 | Isolators | |
1 | Spark Arrester | |
GA100 | 1 | Wheel/Handle Kit |
|
|
|
TROUBLESHOOTING GUIDE
| PROBLEM |
| CAUSE |
| CORRECTION |
|
|
|
|
|
|
| Engine will not start | 1. | Low on fuel or oil. | 1. | Add fuel or oil. |
|
| 2. | Ignition switch in "Off" position. | 2. | Turn to "ON" position |
|
| 3. | Faulty spark plug. | 3. | Replace spark plug. |
|
| 4. | Choke in wrong position. | 4. | Adjust choke accordingly. |
|
| 5. | Fuel | 5. | Open fuel |
|
|
| position. |
|
|
|
| 6. | Unit loaded during | 6. | Remove load from unit. |
|
| 7. Spark plug wire loose. | 7. | Attach wire to spark plug. | |
|
|
|
|
|
|
| No electrical output | 1. | Faulty receptacle. | 1. | Replace. |
|
|
|
|
| |
|
| 2. | Circuit breaker kicked out. | 2. | Depress and reset. |
|
| 3. | Defective capacitor. | 3. | Have Service Center replace |
|
|
|
|
| capacitor. |
|
| 4. | Faulty power cord. | 4. | Repair or replace cord. |
|
|
|
|
| |
| Repeated circuit breaker tripping | 1. Overload | 1. | Reduce load. | |
|
| 2. | Faulty cords or equipment. | 2. | Check for damaged, bare, or |
|
|
|
|
| frayed wires on equipment. |
|
|
|
|
| Replace. |
|
|
|
|
| |
| Generator overheating | 1. Generator overloaded. | 1. | Reduce load. | |
|
| 2. | Insufficient ventilation. | 2. | Move to adequate supply of fresh |
|
|
|
|
| air. |
|
|
|
|
|
|
14 |
|
|
|
|