4-1/2" and 5" Sanding Flap Discs

3. With the guard latch open, rotate the

guard (D) into the desired working

English

Type 27 guard

hubbed sanding

flap disc

Type 27 guard

Quick-Change

backing flange

non-hubbed sanding

flap disc

threaded clamp nut

position. The guard body should be

 

positioned between the spindle and the

 

operator to provide maximum operator

D

protection.

 

4.Close the guard latch to secure the guard

on the gear case. You should not be able to rotate the guard by hand when the latch is closed. Do not operate the grinder with a loose guard or the clamp lever in open position.

5.To remove the guard, open the guard latch, rotate the guard so that the arrows are aligned and pull up on the guard.

NOTE: The guard is pre-adjusted to the diameter of the gear case hub at the factory. If, after a period of time, the guard M becomes loose, tighten the adjusting screw (M) with clamp lever in the closed position.

CAUTION: Do not tighten the adjusting screw with the clamp lever in open position. Undetectable damage to the guard or the mounting hub may result.

CAUTION: If guard cannot be tightened by adjusting clamp, do not use tool and take the tool and guard to a service center to repair or replace the guard.

OPERATION

WARNING: To reduce the risk of serious personal injury, turn tool off and disconnect tool from power source before making any adjustments or removing/installing attachments or accessories. Before reconnecting the tool, depress and release the trigger switch to ensure that the tool is off.