Never fill fuel tank indoors. Never fill fuel tank when engine is running or hot. Do not smoke when filling fuel tank.

Never run engine indoors or in enclosed, poor ventilated areas, engine exhaust contains carbon monoxide, an odorless and

deadly gas.

3.Make sure generator is grounded in accordance with local requirements.

4.All electrical loads MUST be disconnected.

5.Idle control switch must be in the OFF position.

6.Make sure skyhook bolts are tightened and torqued to 11-12 ft.-lbs. (132-144 in.-lbs.).

Engine speed has been factory set to provide safe operation.

Tampering with the engine speed adjustment could result in over- heating of attachments and could cause a fire. Never attempt to “speed-up” the en- gine to obtain more performance. Both the output voltage and frequency will be thrown out of standard by this practice, endangering attachments and the user.

You MUST unplug any load from the generator before starting to prevent permanent damage to any appliances.

TO START THE ENGINE

Never run engine indoors or in enclosed, poor ventilated areas, engine exhaust contains carbon monoxide, an

odorless and deadly gas.

1.Open the fuel shut-off valve.

2.Move the choke control located on the engine to "CHOKE" position. A cold engine may require to be choked longer

than a warm engine.

3. Push ON\OFF\START switch on control panel to the "START" position to start engine. Hold in "START" position no longer than 15 seconds per minute when trying to start engine. Extended cranking can damage the starter motor.

4.When engine starts, gradually move the choke to the "NO Choke" position.

IMPORTANT: Allow generator to run at no load for 5 minutes upon each initial start-up to allow engine and generator to stabilize.

STOPPING ENGINE

1.Disconnect all electrical loads.

2.Place the ON\OFF\START switch to "OFF" position.

3.Close fuel shut-off valve.

CONNECTING ELECTRICAL LOADS

1.Let engine run and warm up for five minutes after starting with no electrical load.

Connect loads in the following manner to prevent damage to equipment:

2.Connect inductive load equipment first, inductive loads consist of refrigerators, freezers, water pumps, air conditioners, or small hand tools. Connect the items that require the most wattage first. See Wattage Calcu- lation Section in this manual.

3.Connect the lights next.

D28469

18- ENG

Page 18
Image 18
DeWalt H1000IS instruction manual To Start the Engine, Stopping Engine, Connecting Electrical Loads, Deadly gas

H1000IS specifications

The DeWalt H1000IS is a robust and versatile inverter generator that has been designed to provide reliable power for both residential and commercial use. Known for its quiet operation and efficiency, the H1000IS stands out in the competitive generator market with a blend of features and advanced technologies.

One of the most prominent characteristics of the DeWalt H1000IS is its inverter technology. This innovative approach ensures that the generator produces clean and stable power, making it ideal for sensitive electronics such as laptops, smartphones, and medical devices. The inverter system also contributes to fuel efficiency, allowing users to maximize running time while minimizing fuel consumption. This is particularly beneficial for those who require power during extended outdoor events or emergencies.

Portability is another key feature of the H1000IS. Weighing in at a manageable weight, it includes a convenient carrying handle that allows users to easily transport the generator to various locations. Whether you need power for a construction site, a family camping trip, or during a power outage at home, the DeWalt H1000IS ensures that you can take electricity wherever you need it.

The generator is equipped with an efficient engine that provides a substantial wattage output. With a power rating of 1000 starting watts and 900 running watts, it can handle a range of devices, from lights and small appliances to power tools. The addition of parallel capability allows users to connect two units to double the available power, which is a significant advantage for larger applications.

Moreover, the H1000IS is designed with user-friendliness in mind. It features a simplified control panel with easy-to-read gauges and indicators. This makes it straightforward to monitor power levels and fuel status at a glance.

Safety is a priority in the DeWalt H1000IS. The generator is equipped with multiple safety features such as low oil shutdown, overload protection, and a robust casing that withstands the rigors of outdoor use.

With its combination of cutting-edge technology, portability, and safety features, the DeWalt H1000IS is an excellent choice for anyone in need of a reliable, efficient, and quiet power source. Whether for work or play, this inverter generator covers a diverse array of power needs, making it a valuable investment for users across various sectors.