7205760100REV03
INSTALLATION GUIDE FOR THE ELECTRIC FIREPLACE
LISTINGS AND CODE APPROVALS
The BF series fireplaces have been tested in accordance with the UL 2021and CSA C22.2 No. 46 standards for fixed and
MODEL SPECIFICATIONS
Model Number | Description | Voltage Volts | Rated Power Watts | Remote | AMPS | |
Control | 120Volt | |||||
|
|
|
| |||
|
|
|
|
|
| |
BF392SD | 39” two sided | 120 | 1500 | STANDARD | 12.5 | |
|
|
|
|
|
|
NOTE: Power ratings shown include the light bulbs and motor
1.Rough in framing opening following the recommended dimensions (Section A: Framing).
NOTE
Section A:
2.Allow 8” of service cable for connecting to the junction box on the fireplace. Remove the outer jacket and strip the individual conductors ½” from the end.
3.Loosen the screw securing junction box cover and remove the cover (FIGURE 1).
4.Remove knockouts if necessary or use the provided cable clamp.
5.Place unit in position in the opening, level with shims if necessary and attach unit to frame using nailing flanges provided.
6.Unit is factory wired for 120 volt installation. Wires L1, N & G are attached to the rear of the junction box cable clamp for easy access.
7.Wire a dedicated, 15 amp fused circuit with three wires (L1, N &G) rated for 120 volts.
8.Place all connectors inside the unit and replace the junction box cover, ensuring that the cable clamp grips only the jacket of service, thermostat and if applicable wall switch lines.
WARNING
Ensure method of installation does NOT obscure the air intake slots on bottom front of unit in any manner.
Air Intake Slots
Junction Box
FIGURE 1 | 1 |