Dimplex CUH05B31T manual Electrical Connection, OPERATION Setting the Thermostat

Models: CUH05B31T

1 6
Download 6 pages 22.41 Kb
Page 5
Image 5
ELECTRICAL CONNECTION

The following steps are shown in FIGURE 3:

1.Locate a stud or other suitable support and install hanger bracket on wall or ceiling. Select location so control knob on back of heater will be reached easily. *

2.Insert carriage bolt into square opening of heater handle.

3.Slide spacer over the carriage bolt shaft and insert in hanger bracket opening and hold them in position.

4.Slide lock washer and thread on nut onto carriage bolt, turn and tighten with wrench.

*DO NOT INSTALL LESS THAN 6 FEET (1.9m) FROM THE FLOOR

FIGURE 3

ELECTRICAL CONNECTION

WARNING: Consult local electrical codes in addition to the following requirements

1.Turn off main power supply at the electrical panel.

2.Route supply wires from circuit breaker to an approved junction box, located near compact unit heater. These supply wires must be two conductor non-metallic sheath cable with ground wire. Each heater should be on an individual, properly fused circuit.

3.Route supply wires from junction box to CUH. These supply wires must be two conductor metallic sheath (BX) cable with ground wire. Alternatively, appropriate conduit can be used.

4.Remove junction box cover of CUH and remove one knockout hole. Insert approved bushing into hole and feed wire cable through. Tighten bushing around cable.

5.Make electrical connection to CUH according to relevant wire diagram. Make connections using approved wire nut connectors and secure the grounding wire to the ground screw on the heater chassis.

6.Replace junction box cover of CUH.

OPERATION (Setting the Thermostat)

1.Before connecting or disconnecting the plug, turn unit off by turning knob fully counter clockwise. (See FIGURE 4)

2.Heater is equipped with a thermostat. To adjust temperature to your individual requirements, turn thermostat control knob clockwise all the way to turn heater on. When room reaches desired temperature, turn thermostat knob counter clockwise until you hear a click. Leave in this position to

maintain room temperature at this setting. For additional heat, turn clockwise until you hear a click again

and heater will turn on. To turn heater to lowest setting, turn thermostat knob counter clockwise all

3

the way.

 

Page 5
Image 5
Dimplex CUH05B31T manual Electrical Connection, OPERATION Setting the Thermostat