Dimplex LA 22PS, LA 26PS, LA 17PS manual Device Information, Type and order code Design

Models: LA 22PS LA 26PS LA 17PS

1 26
Download 26 pages 61.06 Kb
Page 10
Image 10

11

11 Device Information

1Type and order code

2Design

2.1Degree of protection according to EN 60 529 for compact devices and heating components

2.2Installation Location

3

Performance data

 

3.1

Operating temperature limits:

 

 

Heating water flow/return flow 1

°C / °C

 

Air

°C

3.2Temperature spread of heating water at A7 / W35

3.3

Heat output / COP

at A-7 / W35 2

kW / ---

 

 

at A-7 / W45 2

kW / ---

 

 

at A2 / W35 2

kW / ---

 

 

at A7 / W35 2

kW / ---

 

 

at A7 / W45 2

kW / ---

 

 

at A10 / W35 2

kW / ---

3.4

Sound power level

 

dB(A)

3.5Sound pressure level at a distance of 10 m (air outlet side) dB(A)

3.6Heating water flow with an internal pressure differential of m³/h / Pa

3.7

Air flow rate

 

m³/h

3.8

Refrigerant; total filling weight

 

type / kg

4

Dimensions, connections and weight

 

4.1

Device dimensions

 

H x W x L cm

4.2

Device connections to heating system

Inch

4.3

Weight of the transportable unit(s) incl. packing

kg

5

Electrical connection

 

 

5.1

Nominal voltage; fuse protection

 

V / A

5.2

Nominal power consumption 2

A2 W35

kW

5.3

Starting current with soft starter

 

A

5.4

Nominal current A2 W35 / cos ϕ

 

A / ---

6Complies with the European safety regulations

7Additional model features

7.1Defrosting

Type of defrosting Defrosting tray included

7.2Heating water in device protected against icing 6

7.3Performance levels

7.4Controller internal/external

 

LA 17PS

LA 22PS

LA 26PS

 

IP 24

IP 24

IP 24

 

Outdoors

Outdoors

Outdoors

 

Up to 65 / above 18

Up to 65 / above 18

Up to 65 / above 18

 

-20 to +35

-20 to +35

-20 to +35

 

9.3

 

9.5

 

5.0

9.4

 

5.0

 

 

5.0

 

 

3

6.7 / 2.5

 

6.4 / 2.4

7.7 / 2.4

 

7.5 / 2.3

8.7 / 2.4

 

8.4 / 2.2

4

11.4 / 2.6

 

10.8 / 2.5

13.6 / 2.6

 

13.1 / 2.5

14.4 / 2.6

 

13.9 / 2.5

3

 

 

6.0 / 2.2

 

 

7.0 / 2.2

 

 

7.8 / 2.3

4

 

 

10.3 / 2.2

 

 

12.5 / 2.3

 

 

13.3 / 2.3

3

8.7 / 3.2

 

8.3 / 3.0

10.6 / 3.1

 

10.5 / 3.0

11.7 / 3.1

 

11.5 / 3.0

4

14.5 / 3.1

 

14.3 / 3.0

16.7 / 3.1

 

16.5 / 3.0

18.8 / 3.1

 

18.6 / 3.0

3

10.1 / 3.6

 

9.6 / 3.4

12.6 / 3.8

 

12.0 / 3.6

13.7 / 3.6

 

13.3 / 3.5

4

17.3 / 3.5

 

16.6 / 3.4

22.0 / 3.8

 

21.1 / 3.5

24.0 / 3.7

 

22.9 / 3.5

3

 

 

9.3 / 2.9

 

 

11.3 / 3.0

 

 

12.5 / 2.9

4

 

 

16.1 / 2.9

 

 

20.5 / 3.0

 

 

21.6 / 3.0

3

11.8 / 4.1

 

11.4 / 4.1

13.7 / 4.2

 

13.5 / 4.1

15.0 / 4.1

 

14.7 / 4.0

4

19.6 / 3.8

 

19.2 / 3.8

23.4 / 4.0

 

23.2 / 3.9

26.2 / 4.0

 

25.9 / 4.0

 

 

 

 

 

 

 

 

64

68

68

 

37

41

41

 

1.6 / 2900

 

2.0 / 4500

 

3.5 / 13800

2.2 / 3100

 

3.8 / 8900

 

 

3.0 / 10000

 

 

 

5500

8000

8000

 

R290 / 1.8

R290 / 2.2

R290 / 2.5

 

157 x 155 x 85

171 x 168 x 100

171 x 168 x 100

 

G 1 1/4'' external

G 1 1/4'' external

G 1 1/4'' external

 

330

360

371

 

400 / 20 T

400 / 20 T

400 / 25 T

 

4.74

 

5.4

 

5.5

6.1

 

6.2

 

 

4.76

 

 

 

 

 

 

 

 

 

 

23

25

30

 

8.6 / 0.8

 

9.8 / 0.8

 

9.9 / 0.8

11.1 / 0.8

 

11.2 / 0.8

 

 

8.6 / 0.8

 

 

 

 

5

 

5

 

5

 

Automatic

Automatic

Automatic

 

Hot gas

Hot gas

Hot gas

 

Yes (heated)

Yes (heated)

Yes (heated)

 

Yes

Yes

Yes

 

 

2

 

2

 

2

 

External

External

External

 

 

 

 

 

 

 

 

 

 

English

1.See operating limits diagram

2.This data indicates the size and capacity of the system. For an analysis of the economic and energy efficiency of the system, other parameters, such as, in particular, the defrosting capacity, the bivalence point and regulation, should also be taken into consideration. The specified values, e.g. A2 / W55, have the following meaning: 2 °C external air temperature and 55 °C heating water flow temperature.

3.Operation with 1 compressors

4.Operation with 2 compressors

5.See CE declaration of conformity

6.The heat circulating pump and the heat pump controller must always be ready for operation.

www.dimplex.de

E-9

Page 10
Image 10
Dimplex LA 22PS, LA 26PS, LA 17PS manual Device Information, Type and order code Design

LA 22PS, LA 26PS, LA 17PS specifications

Dimplex, a renowned name in electric heating solutions, offers a compelling range of panel heaters designed to provide efficient and comfortable heating for residential and commercial spaces. Among their noteworthy offerings are the LA 17PS, LA 26PS, and LA 22PS models. Each of these panel heaters combines advanced technology, modern design, and user-friendly features to create an ideal heating experience.

The Dimplex LA 17PS is a compact and stylish panel heater, perfect for smaller rooms or spaces where efficiency is key. With a power output of 1.7 kW, it provides rapid and consistent warmth, ensuring that your environment remains cozy. One of the standout features of this model is its advanced digital thermostat, which allows for precise temperature control. Users can easily set their desired temperature, and the heater will automatically adjust its output, optimizing energy usage and maintaining comfort.

Moving on to the Dimplex LA 26PS, this model boasts a higher power output of 2.6 kW, making it suitable for larger areas. Much like the LA 17PS, the LA 26PS is equipped with a digital thermostat, but it also features enhanced programming capabilities. Users can set daily and weekly schedules, ensuring that heating is only active when needed. This programmable functionality not only enhances convenience but also promotes energy savings—an important consideration for environmentally conscious users.

Finally, the Dimplex LA 22PS strikes a balance between the two models with a power output of 2.2 kW. This unit is designed for versatility, making it an excellent choice for various room sizes. The LA 22PS also includes advanced safety features, such as overheat protection and a tip-over switch, ensuring worry-free operation. Its sleek aesthetic seamlessly integrates into any interior décor, making it a functional yet stylish addition to your space.

All three heaters utilize convection heating technology, which ensures even heat distribution across the room. They are also designed with eco-friendly materials and comply with stringent energy efficiency standards. With their user-friendly interfaces, modern designs, and programmable features, the Dimplex LA 17PS, LA 26PS, and LA 22PS models represent the perfect blend of comfort, convenience, and efficiency for any heating requirement.