HYDROSTATIC PUMPS:

CARE AND MAINTENANCE

HYDROSTATIC PUMPS:

Before each use, check to be sure that the cooling fins of the hydrostatic pumps are clean. Excessive accumulation of oil, dirt, or trash may cause the pumps

to overheat. NEVER WASH ACROSS TOP OF RESERVOIR WITH WATER OR STEAM. Fill reservoir as required per the maintenance schedule listed in this book.

HYDROSTAT DRIVE BELT REPLACEMENT PROCEDURE:

To remove hydrostat pump drive belt:

(The hydrostat pump drive is equipped with a spring loaded belt take-up).

1.Raise seat.

2.Remove hold down bolts from belt cover. Remove belt cover.

3.Rotate the spring loaded take-up idler towards the left hand hydro pump to provide belt slack for removal.

4.Remove belt.

To install hydrostat pump drive belt:

1. Rotate the spring loaded take-up idler towards the left hand hydro pump.

2. Install belt per diagram. 3. Re-attach belt cover. 4. Return the seat to the

operating position.