Dixon 2301 manual Care And Maintenance - Model Ztr, Fuel Shut Off Valve, Lubrication

Models: 2301

1 42
Download 42 pages 8.27 Kb
Page 26
Image 26
FUEL SHUT OFF VALVE:

CARE AND MAINTENANCE - MODEL ZTR 2301

FUEL SHUT OFF VALVE:

The fuel shut off valve is located at the bottom rear of the fuel tank.

Always turn the valve to the "OFF" position when the mower is stored or not in use.

LUBRICATION:

CHASSIS: LOCATIONS:

Number of grease zerks used: (4)

SERVICE INTERVALS:

(1) each front wheel caster and each front wheel hub

RECOMMENDED GREASE:

Every 50 hours of operation

 

Name brand wheel bearing or multi-purpose grease

 

Lubricate each front wheel to allow e ven distribution of grease

 

within the wheel, rotate or spin each front wheel after (3) pumps of

 

the grease gun. Repeat process until the appearance of grease is

 

noted completely around each caster axle.

Page 23

Page 26
Image 26
Dixon 2301 manual Care And Maintenance - Model Ztr, Fuel Shut Off Valve, Lubrication