![](/images/new-backgrounds/1083292/8329251x1.webp)
AC Operation Refrigeration Systems
|
|
|
|
|
| PASSAGEMAKER SERIES |
|
|
|
| |
|
|
|
|
|
| 115 and 230 Volt AC Models | |||||
|
|
|
|
|
| Grunert Passagemaker compressors are hermetically | |||||
|
|
|
|
|
| sealed for quiet, efficient operation. Vibration isolators | |||||
|
|
|
|
|
| are incorporated in all mounting platforms to provide | |||||
|
|
|
|
|
| additional noise reduction. |
|
|
|
|
|
|
|
|
|
|
| z Filter/drier is replaceable without |
|
|
| ||
|
|
|
|
|
| refrigerant charge loss. |
|
|
|
|
|
|
|
|
|
|
| z Effectively cools one or multiple boxes of | |||||
|
|
|
|
|
| virtually any configuration. |
|
|
| ||
|
|
|
|
|
| z Sight glass / moisture indicator assembly | |||||
|
|
|
|
|
| to monitor system refrigerant charge. |
|
|
| ||
|
|
|
|
|
| z Remote electrical box is completely |
|
|
| ||
|
|
|
|
|
| enclosed to protect all components. |
|
|
| ||
|
|
|
|
|
| z 5’ harness allows for a dry, |
|
|
| ||
|
|
|
|
|
| accessible mounting location. |
|
|
| ||
|
|
|
|
|
| z Low 12 voltage controls provide an extra | |||||
|
|
|
|
|
| margin of safety. |
|
|
|
|
|
|
|
|
|
|
| Electrical Box Dimensions: |
|
|
| ||
|
|
|
|
|
| 10.875"D x 10.625"W x 4"H |
|
|
| ||
|
|
|
|
|
|
|
|
|
|
| |
| PASSAGEMAKER MODELS |
|
|
|
|
|
|
|
|
| |
| MODEL No. | AC425 | AC450 | AC475 | AC4100Z | AC4150Z | AC4200Z |
| |||
|
|
|
|
|
|
|
|
|
| ||
| Refrigerant Charge: | 26 oz. | 50 oz. | 50 oz. | 50 oz. | 76 oz. | 76 oz. |
| |||
|
|
|
|
|
|
|
|
|
|
|
|
| Capacity BTU/H • 26°F2: | 1850 | 3400 | 5000 |
| 6500 | 9000 |
| 15000 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Capacity BTU/H • 0°F2: | 1650 | 2800 | 4200 |
| 5500 | 7000 |
| 11900 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Electrical |
|
|
|
|
|
|
|
|
|
|
| RLA = 115 V / 230V |
|
|
|
|
|
|
|
|
|
|
| Water Cooled: | 5.9 / 2.9 | 6.7 / 3.0 | 15.2 / 7.7 | / 10.9 | / 10.9 |
| / 18.6 |
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
| Electrical |
|
|
|
|
|
|
|
|
|
|
| RLA = 115 V / 230V |
|
|
|
|
|
|
|
|
|
|
| Air/Water Cooled: | 6.9 / 3.4 | 7.7 / 3.5 | 16.2 / 8.2 | / 11.4 | / 11.4 |
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
| Electrical |
|
|
|
|
|
|
|
|
|
|
| LRA = 115 V / 230V: | 40 / 20.5 | 68 / 34 | 59 / 37 |
| / 56 | / 56 |
| / 107 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Max. Circ. Breaker |
|
|
|
|
|
|
|
|
|
|
| 115 V / 230V: | 15 / 10 | 20 / 10 | 35 / 15 |
| / 25 | / 30 |
| / 40 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Min. Circ. Breaker |
|
|
|
|
|
|
|
|
|
|
| 115 V / 230V: | 10 / 5 | 16 / 7 | 27 / 14 |
| / 20 | / 20 |
| / 30 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Dimensions |
|
|
|
|
|
|
|
|
|
|
| Depth: | 14.1" | 14.1" | 14.1" |
| 20" | 20" |
| 20" |
|
|
| Width: | 13.1" | 13.1" | 13.1" |
| 17" | 17" |
| 17" |
|
|
| Height: | 10.5" | 13.6" | 14.8" |
| 15.3" | 15.3" |
| 16" |
|
|
|
|
|
|
|
|
|
|
|
| ||
| Weight: | 47 lbs. | 78 lbs. | 74 lbs. | 75 lbs. | 77 lbs. | 92 lbs. |
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
2BTU/H ratings are the average rate of heat extraction from holdover plates and are not the capacity of the compressor or condensing unit. These figures are to be used to determine run times to maintain box design temperatures.
26