The hose has to be replaced within the intervals settled in the particular national rules. After having connected the gas bottle, a leak test at all joints and a burner flame test have to be carried out. Use a leak indicating spray or a foaming agent carrying out the leak test. After having opened the bottle valve check the joints for bubbles.
Never use a naked flame to check the appliance for leaks.
5.1.4Categories of appliances
Table of gas pressure
Category | I3P(30) | I 3P(37) | I3P(50) |
| I3+ | I3B/P(50) | I3B/P(30) |
mbar | 30 | 37 | 50 | 50 | 30 | ||
|
|
|
|
|
|
|
|
BE |
|
|
| X |
|
|
|
DK |
|
|
|
|
|
| X |
DE |
|
|
|
|
| X | X |
FI |
|
|
|
|
|
| X |
FR |
|
|
| X |
|
|
|
GR |
|
|
|
| X |
| X |
IE |
| X |
| X |
|
|
|
IS |
|
|
|
|
|
| X |
IT |
|
|
| X |
|
|
|
LU | X |
|
|
|
|
| X |
NL | X |
|
|
|
|
| X |
NO |
|
|
|
|
|
| X |
AT |
|
|
|
|
| X | X |
PT |
| X |
|
| X |
|
|
SE |
|
|
|
|
|
| X |
CH |
|
|
| X |
|
| X |
ES |
|
|
| X |
|
|
|
UK |
| X |
| X |
|
| X |
5.2Cleaning
Before switching the refrigerator on to use it, we recommend that you clean it inside and out, and repeat this at regular intervals.
Use a soft cloth and lukewarm water with a mild detergent. Then rinse the appliance with clean water and dry thoroughly.
Remove dust from the refrigerator unit at yearly intervals using a brush or soft cloth.
ATTENTION
To avoid deterioration of materials:
Do not use soap or hard, abrasive or
Do not allow the door seal to come into contact with oil or grease.
8