5.1.4Categories of appliances

The hose has to be replaced within the intervals settled in the particular national rules. After having connected the gas bottle, a leak test at all joints and a burner flame test have to be carried out. Use a leak indicating spray or a foaming agent carrying out the leak test. After having opened the bottle valve check the joints for bubbles.

Never use a naked flame to check the appliance for leaks.

5.1.4Categories of appliances

Table of gas pressure

Category

I3P(30)

I 3P(37)

I3P(50)

 

I3+

I3B/P(50)

I3B/P(30)

mbar

30

37

50

28-37

30-37

50

30

 

 

 

 

 

 

 

 

BE

 

 

 

X

 

 

 

DK

 

 

 

 

 

 

X

DE

 

 

 

 

 

X

X

FI

 

 

 

 

 

 

X

FR

 

 

 

X

 

 

 

GR

 

 

 

 

X

 

X

IE

 

X

 

X

 

 

 

IS

 

 

 

 

 

 

X

IT

 

 

 

X

 

 

 

LU

X

 

 

 

 

 

X

NL

X

 

 

 

 

 

X

NO

 

 

 

 

 

 

X

AT

 

 

 

 

 

X

X

PT

 

X

 

 

X

 

 

SE

 

 

 

 

 

 

X

CH

 

 

 

X

 

 

X

ES

 

 

 

X

 

 

 

UK

 

X

 

X

 

 

X

5.2Cleaning

Before switching the refrigerator on to use it, we recommend that you clean it inside and out, and repeat this at regular intervals.

Use a soft cloth and lukewarm water with a mild detergent. Then rinse the appliance with clean water and dry thoroughly.

Remove dust from the refrigerator unit at yearly intervals using a brush or soft cloth.

Table of gas pressureATTENTION

To avoid deterioration of materials:

Do not use soap or hard, abrasive or soda-based cleaning agents.

Do not allow the door seal to come into contact with oil or grease.