2.4Installation Instructions
1.Inspect the fireplace according to the safety information and fireplace requirements and have it cleaned and/or upgraded as necessary.
2.If the installation of the unit renders the existing damper control inaccessible, it will be necessary to either secure the damper wide open or remove it entirely. An inaccessible damper, which may close, could cause smoke to enter the room. This creates a potential health hazard.
3.CONNECTOR INSTALLATION: A flue connector may provide acceptable performance, however, we recommend the use of a chimney liner to ensure satisfactory performance. Slip connectors for continuous liners should also be installed. Use Listed Chimney Liners – UL1777,
4.ATTENTION INSTALLER: When positioning the unit in a fireplace opening prior to the flue installation, install the insert into the opening until the top lip of air jacket is flush with fireplace facing.
Figure 2.2 | Figure 2.3 |
4.If
5.Remove the faceplate panels from their box and assemble according to the following instructions.