XD5120 OPERATION
Troubleshooting
Problem | Cause | Action | |
Unit will not | Yellow or red wire not connected or | Check connections for proper | |
turn on | incorrect voltage | voltage (11~16VDC) | |
(no power) |
|
| |
Black wire not connected | Check connection to ground | ||
| |||
|
|
| |
| Fuse blown | Replace fuse | |
Unit has power | Speaker wires not connected | Check connections at speakers | |
(but no sound) |
|
| |
One or more speaker wires touching | Insulate all bare speaker wires | ||
| each other or touching chassis | from each other and chassis | |
| ground | ground | |
|
|
| |
Unit blows | Yellow or red wire touching chassis | Check for pinched wire | |
fuses | ground |
| |
|
|
| |
| Speaker wires touching chassis | Check for pinched wire | |
| ground |
| |
| Incorrect fuse rating | Use fuse with correct rating | |
|
|
| |
Excessive | Unit is not mounted correctly or | Check mounting sleeve and | |
skipping | backstrap is not secure | backstrap support | |
|
|
| |
| Physical defect in media | Check media for scratches | |
| (CD, |
| |
|
|
| |
Err appears on | Load/Eject operation error or disc is | Press eject | |
display | in upside down |
|
Dual Electronics Corp.
Toll Free:
www.dualav.com