Image 12
Troubleshooting

XD5125 OPERATION

Troubleshooting

Problem

Cause

Action

Unit will not

Yellow or red wire not connected or

Check connections for proper

turn on

incorrect voltage

voltage (11~16VDC)

(no power)

Black wire not connected

Check connection to ground

 

 

 

 

 

Fuse blown

Replace fuse

Unit has power

Speaker wires not connected

Check connections at speakers

(but no sound)

One or more speaker wires touching

Insulate all bare speaker wires

 

each other or touching chassis

from each other and chassis

 

ground

ground

 

 

 

Unit blows

Yellow or red wire touching chassis

Check for pinched wire

fuses

ground

 

 

 

 

 

Speaker wires touching chassis

Check for pinched wire

 

ground

 

 

Incorrect fuse rating

Use fuse with correct rating

 

 

 

Excessive

Unit is not mounted correctly or

Check mounting sleeve and

skipping

backstrap is not secure

backstrap support

 

 

 

 

Physical defect in media

Check media for scratches

 

(CD, CD-R or CD-RW)

 

 

 

 

Err appears on

Load/Eject operation error or disc is

Press eject

display

in upside down

 

 

 

 