XD5210 OPERATION
|
| Troubleshooting | |||
|
|
|
|
|
|
Problem |
| Cause |
| Action |
|
Unit will not | Yellow or red wire not connected or | Check connections for proper | |||
turn on | incorrect voltage | voltage (11~16VDC) | |||
(no power) |
|
|
|
|
|
Black wire not connected | Check connection to ground | ||||
|
|
|
|
|
|
| Fuse blown | Replace fuse | |||
Unit has power | Speaker wires not connected | Check connections at speakers | |||
(but no sound) |
|
|
|
|
|
One or more speaker wires touching | Insulate all bare speaker wires | ||||
| each other or touching chassis | from each other and chassis | |||
| ground |
| ground | ||
|
|
|
|
|
|
Unit blows | Yellow or red wire touching chassis | Check for pinched wire | |||
fuses | ground |
|
|
|
|
|
|
|
|
|
|
| Speaker wires touching chassis | Check for pinched wire | |||
| ground |
|
|
|
|
| Incorrect fuse rating | Use fuse with correct rating | |||
|
|
|
|
|
|
Excessive | Unit is not mounted correctly or | Check mounting sleeve and | |||
skipping | backstrap is not secure | backstrap support | |||
|
|
|
|
|
|
| Physical defect in media | Check media for scratches | |||
| (CD, |
|
|
| |
|
|
|
|
|
|
|
|
|
| Error Codes | |
|
|
|
|
| |
Error Code | Cause |
| Action |
| |
ER01 appears on display | High internal temperature |
| Turn unit off for 1 hour |
| |
|
|
|
|
| |
ER02 appears on display | Load/Eject operation error |
| Press eject or RESET |
| |
|
|
|
|
| |
ER03 appears on display | Focus adjustment error |
| Clean or replace media |
| |
|
|
|
| ||
ER04 appears on display | Tracking auto adjustment error | Clean or replace media |
| ||
|
|
|
|
| |
ER06 appears on display | Sled operation error |
| Press eject or RESET |
| |
|
|
|
|
| |
ER07 appears on display | Focus search operation error |
| Press eject or RESET |
| |
|
|
|
|
| |
ER08 appears on display | CLV (PLL) operation error |
| Press eject or RESET |
| |
|
|
|
|
| |
ER09 appears on display | TOC data read error |
| Clean or replace media |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 11 |
|