ANNUAL MAINTENANCE
Inspection of the Spider/Insect Screens
To inspect the Spider/Insect screens:
1.Turn “OFF” gas at source.
2.Remove the cooking grate and the heat distribution plates, exposing the burner tubes.
3.Remove control knobs
4.Remove the two (2) screws and washers holding each valve to the control panel and control knob bezel.
5.Loosen the control panel by removing two (2) screws from each side of the front control panel.
6.Pull control panel away from grill.
7. Remove the four (4) screws that hold the manifold to the manifold bracket.
For Rotisserie Burner tube removal:
Disconnect the rotisserie ignition wire from the ignition module (A).
(A)
Remove two screws and nuts on the
Remove top rear “A” support at the back of grill to get access to Rotisserie burners screws.
Loosen two screws and nuts that secure rotisserie bracket (C) to remove the rotisserie burner.
(B) |
27