Ducane (HVAC) 2AC13 warranty Indoor, Model

Models: 2AC13

1 8
Download 8 pages 58.32 Kb
Page 7
Image 7
Indoor

2AC13 Split System Air Conditioner 13

Cooling Performance with Air Handlers and Furnaces (36, 42, 48, 60)

 

 

 

 

Indoor

 

 

 

 

 

 

 

Refrigerant

 

Refrigerant

 

 

 

 

Model

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Connection

 

Line Size

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outdoor

 

 

 

 

 

Variable

 

 

Rated

Rated

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Speed

SEER

EER

ARI

Sensible

CFM

Outdoor

Indoor

 

 

Model

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Furnace

 

 

Capacity1

Capacity

 

Suction

 

 

 

Piston or Field

 

 

Factory

 

 

 

Suction

Liquid

Suction

Liquid

Liquid

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Installed TXV

 

 

Installed TXV

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RBCS2M36C****P

 

RBCS2M36C****T

---

13.00

11.50

35,000

27,000

1060

3/4

3/8

3/4

3/8

3/4

3/8

 

 

 

RBCS2M36V****P

 

 

---

---

14.00

12.00

35,600

27,400

1060

3/4

3/8

3/4

3/8

3/4

3/8

 

 

 

E(C,M,U)1P36NA

 

E(C,M,U)2T36NA

MPGAV050

13.50

11.50

35,000

27,000

1060

3/4

3/8

3/4

3/8

3/4

3/8

 

 

 

E(C,M,U)1P36NA

 

E(C,M,U)2T36NA

MPGAV075

13.50

11.50

35,000

27,000

1060

3/4

3/8

3/4

3/8

3/4

3/8

2AC13**36P

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E(C,H,M,U)1P36NB

 

E(C,H,M,U)2T36NB

CMPEV100

13.50

11.50

34,800

26,800

1060

3/4

3/8

3/4

3/8

3/4

3/8

 

 

 

E(C,H,M,U)1P36NB

 

E(C,H,M,U)2T36Nb

MPGAV100

13.50

12.00

35,200

27,100

1060

3/4

3/8

3/4

3/8

3/4

3/8

 

 

 

E(C,H,M,U)1P43NB

 

E(C,H,M,U)2T36NB

CMPEV0100

13.50

12.00

35,800

27,600

1060

3/4

3/8

7/8

3/8

3/4

3/8

 

 

 

E(C,H,M,U)1P43NB

 

E(C,H,M,U)2T36NB

MPGAV100

13.50

12.00

35,800

27,600

1060

3/4

3/8

7/8

3/8

3/4

3/8

 

 

 

RBCS2M42C****P

 

RBCS2M42C****T

---

13.00

11.00

39,500

27,600

1250

7/8

3/8

7/8

3/8

7/8

3/8

 

 

 

RBCS2M42V****P

 

 

---

---

13.50

12.00

39,500

27,600

1250

7/8

3/8

7/8

3/8

7/8

3/8

2AC13*42P

 

E(C,H,M,U)1P43NB

 

E(C,H,M,U)2T43NC

MPGAV050

13.50

12.00

40,000

28,000

1400

7/8

3/8

7/8

3/8

7/8

3/8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E(C,H,M,U)1P43NB

 

E(C,H,M,U)2T43NC

MPGAV100

14.00

12.00

40,000

28,000

1400

7/8

3/8

7/8

3/8

7/8

3/8

 

 

 

E(C,M,U)1P49NC

 

 

E(C,M,U)2T49NA

CMPEV125

13.50

11.00

40,000

28,000

1400

7/8

3/8

7/8

3/8

7/8

3/8

 

 

 

E(C,M,U)1P49NC

 

 

E(C,M,U)2T49NA

MPGAV125

14.00

11.50

40,500

28,300

1400

7/8

3/8

7/8

3/8

7/8

3/8

 

 

 

RBCS2M48C****P

 

RBCS2M48C****T

---

13.00

12.00

45,000

32,0º00

1600

7/8

3/8

7/8

3/8

3/4

3/8

 

 

 

RBCS2M48V****P

 

 

---

---

13.50

12.00

45,800

32,000

1600

7/8

3/8

7/8

3/8

3/4

3/8

2AC13*48P

 

E(C,H,U)1P49NC

 

 

E(C,M,U)2T30NB

MPGAV125

14.00

12.00

46,000

32,600

1600

7/8

3/8

7/8

3/8

3/4

3/8

 

 

 

E(C,M,U)1P50NC

 

 

E(C,M,U)2T30NB

MPGAV125

13.50

12.00

45,000

32,000

1600

7/8

3/8

7/8

3/8

3/4

3/8

 

 

 

E(C,M,U)1P62NC

 

 

E(C,M,U)2T36NA

MPGAV125

14.00

12.00

45,500

32,200

1600

7/8

3/8

7/8

3/8

3/4

3/8

 

 

 

RBCS260C****P

 

 

RBCS260C****T

---

13.00

11.00

52,000

38,000

1800

7/8

3/8

7/8

3/8

1-1/8

3/8

 

 

 

RBCS2M60V****P

 

 

---

---

13.50

11.50

52,000

38,000

1800

7/8

3/8

7/8

3/8

1-1/8

3/8

2AC13*60P

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E(C,M,U)1P49NC

 

 

E(C,H,U)2T49NC

MPGAV125

13.50

11.00

53,000

38,600

1800

7/8

3/8

7/8

3/8

1-1/8

3/8

 

 

 

E(C,H,M,U)1P62NC

 

 

E(C,H,U)2T62NC

MPGAV125

13.50

11.50

54,000

39,400

1800

7/8

3/8

7/8

3/8

1-1/8

3/8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

**

= B, L, BC, LC

1

Certified in accordance with Unitary Air Conditioner Certification Program, which is based on ARI Standard 210/240.

 

*

= B, L

 

2

Required to achieve ARI rating.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A blower time delay is required to achieve ARI rating.

Indoor

Metering

Device

Req'd

Optional

Field

Indoor2

Orifice

Installed

Orifice

 

.076

A2TXV01

.076

A2TXV01

.076

A2TXV01

.076

A2TXV01

.076

A2TXV01

.076

A2TXV01

.076

A2TXV01

.076

A2TXV01

.080

A2TXV02

.080

A2TXV02

.080

A2TXV02

.080

A2TXV02

.080

A2TXV02

.080

A2TXV02

.088

A2TXV02

.088

A2TXV02

 

 

.088

A2TXV02

 

 

.088

A2TXV02

.088

A2TXV02

.098

A2TXV02

.098

A2TXV02

.098

A2TXV02

.098

A2TXV02

 

 

Page 7