Blower Performance - Belt Drive
| Motor | Blower | Motor | Motor | Blower | Belt | Temp. | CFM @ .20 | |
| ext. static | ||||||||
Model | Size | Pulley | Pulley | Pulley | Size | Rise | |||
Size | pressure | ||||||||
| (hp) | (in.) | Adjustment | (in.) | (in.) | (oF) | |||
|
| in. W.C. | |||||||
|
|
|
|
|
|
|
| ||
RLUF80C57B08 | 1/6 | 10 x 8 | 3 1/4 | 1 Turn | 7 | 40 | 820 | ||
RLUF80C84/95B10 | 1/4 | 10 x 8 | 4 | Closed | 7 | 41 | 1,170 | ||
|
|
|
|
|
|
|
| ||
RLUF80C112/125B16 | 3/4 | 12 x 9 | 4 | Closed | 7 | 41 | 1,550 | ||
|
|
|
|
|
|
|
|
1Low Fire Nozzle
2High Fire Nozzle
Blower Performance - Direct Drive
| Motor | Blower | Temp. | Blower |
|
| CFM @ ext. static pressure in. W.C. |
|
| ||||
Model | Size | Rise |
|
|
|
|
|
|
|
| |||
Size | Speed | .20 | .30 | .40 | .50 | .60 | .70 | .80 | .90 | ||||
| (hp) | (oF) | |||||||||||
|
|
| |||||||||||
|
|
|
| High | 1,412 | 1,356 | 1,299 | 1,222 | 1,154 | 1,075 | 988 | 890 | |
RLUF80C57/72D12 | 1/3 | 10 x 8 | Med High | 1,260 | 1,217 | 1,172 | 1,120 | 1,060 | 988 | 914 | 797 | ||
Med | 1,040 | 1,025 | 991 | 960 | 910 | 860 | 790 | 680 | |||||
|
|
|
| ||||||||||
|
|
|
| Low | 887 | 878 | 850 | 830 | 787 | 742 | 680 | 605 | |
|
|
|
| High | 1,756 | 1,693 | 1,940 | 1,590 | 1,495 | 1,361 | 1,250 | 1,095 | |
RLUF80C84/95D16 | 1/2 | 10 x 10 | Med High | 1,445 | 1,425 | 1,400 | 1,335 | 1,287 | 1,200 | 1,065 | 965 | ||
Med | 1,191 | 1,181 | 1,147 | 1,110 | 1,054 | 985 | 894 | 827 | |||||
|
|
|
| ||||||||||
|
|
|
| Low | 989 | 979 | 961 | 926 | 880 | 835 | 775 | 690 | |
|
|
|
| High | 2,204 | 2,140 | 2,058 | 2,000 | 1,900 | 1,850 | 1,680 | 1,560 | |
RLUF80C112/125D20 | 3/4 | 12 x 11 | Med High | 1,760 | 1,725 | 1,670 | 1,615 | 1,560 | 1,480 | 1,390 | 1,313 | ||
Med | 1,520 | 1,496 | 1,450 | 1,400 | 1,360 | 1,315 | 1,250 | 1,165 | |||||
|
|
|
| ||||||||||
|
|
|
| Low | 1,366* | 1,329* | 1,304* | 1,250* | 1,210* | 1,180* | 1,120* | 1,040* |
*Not recommended for heating. Temperature rise may be outside acceptable range.
Alternate Motors for Cooling Combinations - Belt Drive
| Nominal | Motor |
| Motor | Motor | Blower | Belt | CFM @ ext. static pressure - in. W.C. | |||
Model | Cooling | Blower | |||||||||
Capacity | Size | Size | Pulley | Pulley | Pulley | Size |
|
|
|
| |
| (hp) | (in.) | Adjustment | (in.) | (in.) |
|
|
|
| ||
| (tons) |
|
|
|
|
| |||||
|
|
|
|
|
|
| .20 | .30 | .40 | .50 | |
|
|
|
|
|
|
|
| ||||
RLUF80C57B08 | 2.0 - 2.5 | 1/4 | 10 x 8 | 4 | Closed | 7 | 41 | 1,170 | 1,154 | 1,070 | 975 |
RLUF80C84/95B10 | 2.0 - 3.5 | 1/2 | 10 x 8 | 4 | Closed | 6 | 39 | 1,550 | 1,495 | 1,430 | 1,370 |
RLUF80C112/125B16 | 4.0 - 5.0 | 3/4 | 12 x 9 | 3 1/4 | Closed | 5 | 36 | 1,990 | 1,925 | 1,850 | 1,820 |
Note: Field converted with different size motor for cooling applications.