Blower Performance - Belt Drive

 

Motor

Blower

Motor

Motor

Blower

Belt

Temp.

CFM @ .20

 

ext. static

Model

Size

Pulley

Pulley

Pulley

Size

Rise

Size

pressure

 

(hp)

(in.)

Adjustment

(in.)

(in.)

(oF)

 

 

in. W.C.

 

 

 

 

 

 

 

 

RLUF80C57B08

1/6

10 x 8

3 1/4

1 Turn

7

40

55-85

820

RLUF80C84/95B10

1/4

10 x 8

4

Closed

7

41

55-851

1,170

60-902

 

 

 

 

 

 

 

 

RLUF80C112/125B16

3/4

12 x 9

4

Closed

7

41

50-801

1,550

60-902

 

 

 

 

 

 

 

 

1Low Fire Nozzle

2High Fire Nozzle

Blower Performance - Direct Drive

 

Motor

Blower

Temp.

Blower

 

 

CFM @ ext. static pressure in. W.C.

 

 

Model

Size

Rise

 

 

 

 

 

 

 

 

Size

Speed

.20

.30

.40

.50

.60

.70

.80

.90

 

(hp)

(oF)

 

 

 

 

 

 

 

High

1,412

1,356

1,299

1,222

1,154

1,075

988

890

RLUF80C57/72D12

1/3

10 x 8

50-80

Med High

1,260

1,217

1,172

1,120

1,060

988

914

797

Med

1,040

1,025

991

960

910

860

790

680

 

 

 

 

 

 

 

 

Low

887

878

850

830

787

742

680

605

 

 

 

 

High

1,756

1,693

1,940

1,590

1,495

1,361

1,250

1,095

RLUF80C84/95D16

1/2

10 x 10

50-80

Med High

1,445

1,425

1,400

1,335

1,287

1,200

1,065

965

Med

1,191

1,181

1,147

1,110

1,054

985

894

827

 

 

 

 

 

 

 

 

Low

989

979

961

926

880

835

775

690

 

 

 

 

High

2,204

2,140

2,058

2,000

1,900

1,850

1,680

1,560

RLUF80C112/125D20

3/4

12 x 11

45-75

Med High

1,760

1,725

1,670

1,615

1,560

1,480

1,390

1,313

Med

1,520

1,496

1,450

1,400

1,360

1,315

1,250

1,165

 

 

 

 

 

 

 

 

Low

1,366*

1,329*

1,304*

1,250*

1,210*

1,180*

1,120*

1,040*

*Not recommended for heating. Temperature rise may be outside acceptable range.

Alternate Motors for Cooling Combinations - Belt Drive

 

Nominal

Motor

 

Motor

Motor

Blower

Belt

CFM @ ext. static pressure - in. W.C.

Model

Cooling

Blower

Capacity

Size

Size

Pulley

Pulley

Pulley

Size

 

 

 

 

 

(hp)

(in.)

Adjustment

(in.)

(in.)

 

 

 

 

 

(tons)

 

 

 

 

 

 

 

 

 

 

 

 

.20

.30

.40

.50

 

 

 

 

 

 

 

 

RLUF80C57B08

2.0 - 2.5

1/4

10 x 8

4

Closed

7

41

1,170

1,154

1,070

975

RLUF80C84/95B10

2.0 - 3.5

1/2

10 x 8

4

Closed

6

39

1,550

1,495

1,430

1,370

RLUF80C112/125B16

4.0 - 5.0

3/4

12 x 9

3 1/4

Closed

5

36

1,990

1,925

1,850

1,820

Note: Field converted with different size motor for cooling applications.