System Input Connector

The System In interface connector is one of the primary communications links between the DPC II / II+ input port and the user automation equipment. This connector provides the automation with dedicated communication lines that allow the automation to control the beginning and the end of a welding sequence.

 

 

 

 

 

 

 

 

 

 

 

 

 

Pin Number

 

 

DPC Signal Name

 

 

DPC Signal Type

 

 

 

1

 

 

Power Supply

 

+22 VDC (250 mA max)

 

 

2

 

 

Ground

 

22VDC Return

 

 

3

 

 

Isolated Operate Input

 

Input

 

 

4

 

 

Isolated Input Common 1

 

Common for pin 3, 5, 9

 

 

5

 

 

Isolated Press Control 2

 

Input

 

 

6

 

 

Not Used

 

Not Used

 

 

7

 

 

Ground

 

+22VDC Return

 

 

8

 

 

Non Isolated Operate

 

Input

 

 

9

 

 

Isolated Automation Stop /

 

Input

 

 

 

 

 

 

Automation End of Weld 3

 

 

 

 

 

10

 

 

Not Used

 

Not Used

 

 

11

 

 

Hand Probe Press Inhibit

 

Input

 

 

12

 

 

MPC Probe/Setup Bit 0 4

 

Input

 

 

13

 

 

MPC Probe/Setup Bit 1 4

 

Input

 

 

14

 

 

MPC Probe/Setup Bit 2 4

 

Input

 

 

15

 

 

Front Panel Control Lock

 

Input

 

 

 

 

 

 

 

 

 

 

 

 

Notes:

1.SH707 on the 110-3606 system I/O PCB must be configured to the JU728 position when this common is used.

2.This input requires the optional 110-3938 press control module. Configuration of the SH901 Jumper on the 110-3938 press control module may also be required.

3.This input is configured for use as Automation End of Weld at the factory. Jumper SH704 must be reconfigured on the 110-3606 System I/O board to permit use of the Isolated Automation Stop feature.

4.The MPC probe bit functionality requires the optional MPC feature. The Setup bit functionality is available on all DPC II+ systems. Please refer to the DPC manual for further details on this feature.