062210 4
The TPG automatically generates only the Red primary (75IRE).
5. Enter the measured Red-x value. Note the indicators reflect only the output of
the Test Pattern Generator.
6. Select Red-y and enter the measured Red-y value
7. Repeat step 4,5 and 6 with Green-x and Green-y
The TPG automatically generates only Green primary (75IRE).
8. Repeat step 4,5 and 6 with Blue-x and Blue-y
The TPG automatically generates only Blue primary (75IRE).
9. Repeat step 4,5 and 6 with White-x and White-y
The TPG automatically generates only White primary (75IRE).
10. Output chromaticity should now match your display’s actual chroma response.
If necessary, the chroma and luma can now be fine-tuned using the Color Gamut
and Gray Scale controls.

1.2 CMS Bypass

In some cases, it is helpful to bypass the CMS when calibrating a display (see User
Chromaticity Control above). The CMS Bypass control is available in the Output Setup
menu.
Main Menu > Output Setup > CMS Bypass
On Signals coming into the iScan Duo bypasses the
Color Management System.
Off (default) The Color Management System is enabled.
2. Per input per format saved settings
Input settings are now saved per format supported by the input. Different inputs
support different formats. For example, Video (composite), S-Video inputs support
NTSC (480i 60Hz), PAL (576i 50Hz), 240p 60Hz and 288p 50Hz, while Component video
and HDMI inputs can support other formats including HD and PC formats.
The iScan Duo will save input settings for each format (if supported by the input) below.