Illustration 4.2: Pin-assignment of CAN jack and CAN plug
Pin | Name | | Colour |
| | |
T568A | | T568B |
| | |
| | | | |
2 | CAN_GND | Green | | Orange |
| | | | |
4 | CAN_H (+) | | Blue |
| | | |
5 | CAN_L (-) | | Blue striped |
| | | | |
Table 4.3: Overview CAN plug
4 CONTROL PORT
The CONTROL PORT of the RCM-810 provides two control inputs, two control outputs and reference connections for +5V and ground. The control inputs are configurable via IRIS-Net™. They can be used for example for switching between power on / standby modes. The two control contacts IN1 and IN2 are internally connected via pull-up resistors and carry +5V (open). The control inputs can be activated using external switches, pushbuttons or relays to connect them to ground potential (pin 3). The two control outputs OUT1 and OUT2 are open collector outputs, which are highly resistive in the non-active state (off). In active state (on) the outputs are connected to ground. The control outputs are configurable via IRIS-Net™ and are used to signal internal states. LEDs, indicators or relays can be driven directly. The +5V reference connector provides voltage supply for connected components.
CAUTION:
The maximally allowable current at the +5V output is 200 mA.
System Example
16 Owner‘s Manual