Automatic water heater start:

Automatic water heater start:

When water temperature is 1˚F (0.5˚C) lower than the Set Point, the heater will automatically turn on until water temperature reaches Set Point plus 1˚F (0.5˚C).

The "Heater" indicator lights up when the heater is on. It flashes when there is a request for more heat but the heater has not yet started.

N.B.: If your system is configured in Low Current Mode, the heater will not start if a pump is on at high speed.

Economy mode:

Press Econo key to switch from Normal mode to Economy mode. In Economy mode, system maintains temperature at the desired Set Point during filter cycles only. Set Point is 20˚F (11˚C) below the Normal mode Set Point for the rest of the time. In Economy mode, the display will toggle between the current water temperature and the "Econ" message.

PROGRAMMING FILTER CYCLE DURATION

The system automatically performs two filter cycles per day, at 12-hour intervals.

During a filter cycle: Pump 2 runs for one minute, then Pump 1 runs at low speed for the programmed number of hours The "Filter Cycle" indicator lights up when the filter cycle is on. To set filter cycle duration:

Press and hold Filter key until the display shows "xx", representing the currently set filter cycle duration in hours.

Use Up or Down arrow keys to change setting.

0 = no filtration

12 = continuous filtration

When the desired setting is dis- played, press Filter key to confirm. A filter cycle starts immediately.

Note: Light needs to be turned off before the filter cycle can be programmed.

The filter cycle is suspended if the water temperature raises more than 2˚F (1˚C) above Set Point or if spa is in use (pumps started manually). The "Filter" icon will flash (on 0.5 second, off 0.5 second, on 0.5 sec- ond, off 1.5 second).

N.B.: After a power failure, the filter cycle duration will return to its default value (2 hours). In this case, the first filter cycle will start one minute after power has been restored.

TROUBLESHOOTING

Pumps have started up for one minute on several occasions and "Filter Cycle" indicator is flashing.

3 flashing dots are displayed.

Water temperature is flashing.

Not a bug but a feature!

Our Smart Winter Mode protects your spa from the cold by automatically turning pumps on for one minute several times a day to prevent water from freezing in pipes.

A problem has been detected.

Do not enter the water! Check and open water valves. Clean filter if necessary. Check water level. Add water if needed.

Shut power off and power your spa up again to reset the system.

Call your dealer or service supplier if problem persists.

Water temperature in the spa has reached 112˚F (44˚C).

Do not enter the water! Allow water to cool down. The system will reset automatically when water temperature reaches 109˚F (43˚C).

Call your dealer or service supplier if problem persists.

The display is flashing.

A power failure has occurred.

 

Press any key to reset the system, then reprogram all

 

desired parameters.