Eagle Electronics 640c manual Speed/Temperature Sensors

Models: 640c

1 108
Download 108 pages 43.63 Kb
Page 32
Image 32

3.Press the transducer into the epoxy, twisting and turning it to force any air bubbles out from under the transducer face. Stop pressing when you bottom out on the hull. When you're finished, the face of the trans- ducer should be parallel with the hull, with a minimum amount of ep- oxy between the hull and transducer.

4.Apply a weight, such as a brick, to hold the transducer in place while the epoxy cures. Be careful not to bump the transducer while the epoxy is wet. Leave the weight in place for a minimum of three hours. Allow the epoxy to cure for 24 hours before moving the boat.

5.After the epoxy has cured, route the cable to the sonar unit and it's ready to use.

Speed/Temperature Sensors

This unit can accept as many as two temperature sensors, which can be used to monitor the temperature of surface water, a live well or some other location. These units can also accept an optional speed sensor for showing speed and distance traveled. However, you can only use one ac- cessory at a time. If you would like to use a speed sensor and a second temperature sensor at the same time, you will need a combination device.

NOTE:

This unit is packed with a transducer containing a built-in temp sensor. The SeaFinder package also includes a speed sensor. If you have a FishMark and want a speed sensor or additional temp sensor, see the Accessory Ordering Information in the back of this manual.

If a second temp sensor is used, it must be the model TS-2U. This model has a fixed electronic "address" which designates it as the second of two temp sensors. Dual temperatures are only displayed on the Full Chart page. The Large Digital page will only display the primary tem- perature sensor. See the following wiring diagram for temperature and speed sensor combinations.

26

Page 32
Image 32
Eagle Electronics 640c manual Speed/Temperature Sensors